2015-09-15 11:57:20 | ELECTRIC WAS REVIEWED SEPARATELY UNDER PERMIT #15080450 |
2015-09-10 15:09:21 | BUILDING PLAN REVIEW |
| W. P. B. PERMIT: 15090069 |
| ADD: 3716 S DIXIE HWY |
| CONT: C & S EXPERTISE INC. |
| TEL: (561)436-5355 |
| E-MAIL: ?????????? |
| |
| 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH |
| AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| ADMINISTRATION, |
| |
| 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. |
| ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND |
| SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE |
| FLORIDA BUILDING CODE, BUILDING. |
| |
| 1ST REVIEW |
| DATE: THURS. SEPT. 10/2014 |
| ACTION: DENIED |
| |
| 1) THE PLANS SUBMITTED HAVE NO DESIGNER. THE PERSON |
| RESPONSIBLE (QUALIFIER) FOR THE CONTRACTOR IS TO PRINT |
| THEIR NAME, SIGN THEIR NAME AND PRINT THEIR LICENSE |
| NUMBER ON THE PLANS. |
| |
| 2) THE NOTE FOR THE FLOOR/ CEILING TO HAVE DRYWALL ON |
| EQUIPMENT PLATFORMS CATES TO USE OF 5/8 INCH GYPSUM |
| BOARD ON EITHER SIDE. I BELIEVE THIS IS A MIS-STATEMENT |
| 5/8 INCH GYPSUM WILL NOT MEET THE REQUIRED FLOOR LOADS |
| THAT WILL BE APPLIED. 2014 FBC-B TABLE 1607.1( 28) |
| ACCESSIBLE CEILINGS. |
| |
| 3) PLEASE NOTE ON THEPLANS, THE HEIGHT OF THE GRAB BARS |
| SHOW TO THE CENTER OF THE BAR. IN THE 2014 FL |
| ACCESSIBILITY CODE 609.4 POSITION OF GRAB BAR, THE |
| HEIGHT IS MEASURED TO THE TOP OF THE GRIPPING SURFACE, |
| 33-36 INCHES, NOT CENTERLINE. |
| |
| 4) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION |
| & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS |
| NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| COOPERATION. |
| |