2015-09-08 11:34:39****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. FOR BEDROOM WINDOWS, REVISE PLAN TO EXISTING
 CONDITIONS (TYPE OF WINDOW) AND OPENING SIZE FOR
 BEDROOMS, FBC R310, FBC EB 704.1. THE CLEAR OPENING
 CANNOT BE REDUCED BY MORE THAN 5%.
  
 TO PROVIDE FURTHER CLARIFICATION REGARDING INFORMATION
 NEEDED FOR BEDROOM WINDOWS WHICH ARE LESS THAN 51" IN
 HEIGHT:
  
 STATE WHAT TYPE OF WINDOW IS THERE NOW IN THE BEDROOMS
 - AWNING, CASEMENT, SINGLE HUNG?
  
 STATE WHAT THE EXISTING CLEAR OPENING DIMENSIONS ARE.
 CLEAR OPENING IS THE OPENING WHICH EXISTS WHEN THE
 WINDOW IS FULLY OPEN.
  
 STATE WHAT THE PROPOSED CLEAR OPENING DIMENSIONS ARE.
 THIS CAN BE OBTAINED FROM THE MANUFACTURER.
  
 DIMENSIONS PROVIDED ARE THE DIMENSIONS WHEN BOTH PANELS
 ARE REMOVED FROM THE WINDOW. EITHER EXPLAIN HOW THIS
 CAN BE DONE FROM THE OUTSIDE (RESCUE OPENING) OR REVISE
 TO INCLUDE CLEAR OPENING DIMENSIONS (WINDOW IN OPEN
 POSITION BUT NOT REMOVED FROM FRAME).
  
  
  