Plan Review Notes
Plan Review Notes For Permit 15081138
Permit Number 15081138
Review Stop G
Sequence Number 1
Notes
Date Text
2015-09-03 14:33:341) THE PLANS SHOW A NEW TANKLESS WATER HEATER TO BE
 INSTALLED. GAS SHALL BE INSTALLED UNDER A SEPARATE
 PERMIT AND 2 COPIES OF A GAS RISER DIAGRAM SHALL BE
 SUBMITTED ALONG WITH TWO COPIES OF MANUFACTURER'S
 SPECIFICATIONS SHOWING THAT THE DEVICE IS LISTED AND
 LABELED IN ACCORDANCE WITH THE 2014 FBC-RESIDENTIAL
 SEC. G2404.3.
 2) SUBMIT A WATER PIPING RISER DIAGRAM FOR THE TANKLESS
 WATER HEATER SHOWING THE COLD WATER LINE SIZE AND
 CONNECTION TO THE EXISTING SYSTEM AND THE HOT WATER
 PIPING CONNECTION TO THE EXISTING SYSTEM. WPB AMEND. TO
 FBC SEC. 107.3.5.3.
 3) THE PLANS ARE SEVERELY DEFICIENT IN INFORMATION FOR
 A GAS REVIEW. COMPLY WITH ALL THE FOLLOWING COMMENTS:
 4). SUBMIT AN ISOMETRIC DRAWING THAT CLEARLY SHOWS THE
 LENGTH OF ALL CUT SECTIONS OF PIPE PER FBC-2014 FUEL
 GAS, SECS. 402.4.1, 402.4.2.
  
 5) SHOW TYPE OF PIPING MATERIAL BEING INSTALLED, ALL
 PIPE SIZES, AND THE EHD NUMBER OF CORRUGATED STAINLESS
 STEEL TUBING FOR EACH PIPE SIZE IF BEING USED. WPB
 AMENDMENTS TO FBC SEC. 107.2.1.
  
 6) BTU LOAD OF EACH APPLIANCE AND THE TOTAL BTU LOAD ON
 THE SYSTEM. REFER TO THE FBC-2014 FUEL GAS SECS. 401.8
 THRU 402.6.1 AND TABLES 402.4(1) THRU 402.4(37).
  
 7) SHOW THE DISTANCE FROM THE POINT OF DELIVERY,
 (METER), TO THE MOST REMOTE OUTLET IN THE BUILDING
 AND/OR SYSTEM PER THE FBC-2014 FUEL GAS APPENDIX A ?
 USE OF CAPACITY SECTION A.3.1(4) & 2014 FUEL GAS CODE
 SEC. 402.4.1.
  
 8) SUBMIT MANUFACTURER?S SPECIFICATION SHEETS FOR ALL
 GAS EQUIPMENT TO VERIFY COMPLIANCE WITH STANDARDS NFPA
 54, NFPA 58, AND FBC-2014 FUEL GAS SEC. 402.2, AND
 301.3. GAS APPLIANCES SHALL BE LISTED AND LABELED PER
 SEC.301.3. THE SUBMITTED DOCUMENTS DO NOT SHOW
 COMPLIANCE.
  
 9) CLARIFY COMMENT #1 "PVC WILL CONTINUE TO NEXT
 DWELLING AT A LATER DATE." THE UNDERGROUND SANITARY
 /WATER SERVICE LATERALS CANNOT CROSS THROUGH THE
 ADJACENT PROPERTY WITHOUT A RECORDED UTILITY EASEMENT.
 UTILITY EASEMENTS, EASEMENT LOCATION AND ASSOCIATED
 RESTRICTIVE PROPERTY COVENANTS ARE TO BE SUBMITTED TO
 THE BUILDING OFFICIAL FOR REVIEW AND APPROVAL PRIOR TO
 RECORDING. SAID DOCUMENTS SHALL BE RECORDED AND PROOF
 OF RECORDING ON THE PLAT, AND ACCEPTANCE BY THE CITY
 SURVEYOR, SHALL BE PROVIDED.
 10) SUBMIT A SANITARY AND WATER RISER DIAGRAM.THE PLAN
 DRAWING SUBMITTED IS CONFUSING AND UNCLEAR. WPB AMEND.
 TO FBC SEC. 107.3.5.3.
 11) THE DRAWING SHOWS THE WATER AND SANITARY BEING
 REPLACED IN A BATHROOM. HOW IS THIS PIPE BEING
 INSTALLED? WILL THERE BE ANY TUNNELING UNDER THE
 EXISTING SLAB? IF SO, A CLEAR AND LEGIBLE SANITARY
 RISER DIAGRAM SHALL BE SUBMITTED SHOWING ALL PIPE
 SIZES, CONNECTION POINTS TO EXISTING PIPING, HOW THE
 NEW PIPE WILL BE SUPPORTED, THE TYPE OF ADAPTERS USED
 FOR THE CONNECTIONS TO EXISTING PIPE, AND THE LOCATIONS
 OF REQUIRED CLEANOUTS. DETAILS AND BACKFILLING
 PROCEDURES SHALL BE SUBMITTED THAT CLEARLY SHOW HOW THE
 STRUCTURAL INTEGRITY OF THE CONCRETE SLAB WILL BE
 MAINTAINED DURING EXCAVATION AND BACKFILLING.
 STRUCTURAL FOAM IS NOT PERMITTED BELOW GROUND PER THE
 FLORIDA BUILDING CODE, RESIDENTIAL, SECTION 318 AND THE
 FLORIDA BUILDING CODE, BUILDING, SECTION 2603.8.
 12) A CLEANOUT IS REQD. AT THE SEWER CONNECTION TO THE
 CITY LATERAL.
 13) THE PLUMBING WORK AND GAS SHALL BE TWO SEPARATE
 PERMIT APPLICATIONS.SUBMIT SEPARATE PERMIT APPLICATIONS
 AND PLANS FOR THE PLUMBING WORK AND THE GAS WORK. THERE
 IS ALSO ANOTHER PERMIT APPLICATION FOR SOME WORK BEING
 DONE AT THIS LOCATION THAT SHOWS A NEW TANKLESS WATER
 HEATER BUT HAS NO GAS NOR PLUMBING PIPING SHOWN ON IT.
 CLARIFY.
  
 PLEASE CONTACT ME AS THIS SUBMITTAL IS EXTREMELY
 CONFUSING.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  
  
  
  
  
  
  