2015-08-31 19:18:52RESIDENTIAL (R3) RE-ROOF BUILDING REVIEW COMMENTS.
 CODE: FBC-RESIDENTIAL, 5TH EDITION (2014).
  
 1- ORIGINALLY THIS HOUSE WAS DESIGNED TO HAVE SHINGLES
 ROOFING. PROPOSAL TO INSTALL CLAY TILES REQUIRES
 ENGINEERING ANALYSIS TO VERIFY IF THE STRUCTURE IS
 ADEQUATE TO RECEIVE THE ADDITIONAL LOAD. SEC. 107.2.1.3
 CITY AMENDMENTS.
  
 2- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 FAC 61G20-3.002(33) FOR THE TILE ADHESIVE LISTED ON THE
 CLAY TILE NOA.
  
 3- FLAT ROOF FLORIDA PRODUCT APPROVAL FL5680-R15
 SUBMITTED: CLEARLY MARK WHICH APPROVED ASSEMBLY IS
 GOING TO BE INSTALLED TO VERIFY COMPLIANCE WITH THE
 DESIGN PRESSURES OF SEC. R301. THIS BUILDING IS LOCATED
 IN EXPOSURE "C". IF THE SELECTED ASSEMBLY DOESN'T MEET
 THE DESIGN PRESSURES FOR ALL ROOF ZONES, THEN SIGNED
 AND SEALED RAS 117 CALCULATIONS WOULD BE REQUIRED. SEE
 NOTE #8 ON PAGE 2 OF 76.
  