2015-12-10 13:29:58 | 1ST REVIEW: FBC 2014 5TH ED. NEC 2011/RESIDENTIAL |
| MARIO VALDES |
| ELECTRICAL PLAN EXAMINER |
| 516-805-6700 |
| [email protected] |
| ALTERNATE CONTACT |
| PHIL PETTY |
| 561-805-6742 |
| [email protected] |
| |
| |
| (A) DWELLING UNITS. ALL 125-VOLT, SINGLE-PHASE, 15- AND |
| 20- |
| AMPERE RECEPTACLES INSTALLED IN THE LOCATIONS SPECIFIED |
| IN |
| 210.8(A)(1) THROUGH (8) SHALL HAVE GROUND-FAULT |
| CIRCUITINTERRUPTER |
| PROTECTION FOR PERSONNEL. |
| (1) BATHROOMS |
| (2) GARAGES, AND ALSO ACCESSORY BUILDINGS THAT HAVE A |
| FLOOR |
| LOCATED AT OR BELOW GRADE LEVEL NOT INTENDED AS |
| HABITABLE |
| ROOMS AND LIMITED TO STORAGE AREAS, WORK AREAS, |
| AND AREAS OF SIMILAR USE |
| |
| (A) GENERAL PROVISIONS. IN EVERY KITCHEN, FAMILY ROOM, |
| DINING ROOM, LIVING ROOM, PARLOR, LIBRARY, DEN, |
| SUNROOM, |
| BEDROOM, RECREATION ROOM, OR SIMILAR ROOM OR AREA OF |
| DWELLING UNITS, RECEPTACLE OUTLETS SHALL BE INSTALLED |
| IN ACCORDANCE |
| WITH THE GENERAL PROVISIONS SPECIFIED IN 210.52(A)(1) |
| THROUGH (A)(3). |
| (1) SPACING. RECEPTACLES SHALL BE INSTALLED SUCH THAT |
| NO |
| POINT MEASURED HORIZONTALLY ALONG THE FLOOR LINE OF ANY |
| WALL |
| SPACE IS MORE THAN 1.8 M (6 FT) FROM A RECEPTACLE |
| OUTLET. |
| (2) WALL SPACE. AS USED IN THIS SECTION, A WALL SPACE |
| SHALL |
| INCLUDE THE FOLLOWING: |
| (1) ANY SPACE 600 MM (2 FT) OR MORE IN WIDTH (INCLUDING |
| SPACE MEASURED AROUND CORNERS) AND UNBROKEN ALONG |
| THE FLOOR LINE BY DOORWAYS AND SIMILAR OPENINGS, |
| FIREPLACES, |
| AND FIXED CABINETS |
| (2) THE SPACE OCCUPIED BY FIXED PANELS IN EXTERIOR |
| WALLS, |
| EXCLUDING SLIDING PANELS |
| (3) THE SPACE AFFORDED BY FIXED ROOM DIVIDERS, SUCH AS |
| FREESTANDING BAR-TYPE COUNTERS OR RAILINGS |
| |
| FOR DWELLING UNITS, ATTACHED GARAGES, AND DETACHED |
| GARAGES WITH ELECTRIC POWER, AT LEAST ONE WALL SWITCH? |
| CONTROLLED LIGHTING OUTLET SHALL BE INSTALLED TO |
| PROVIDE ILLUMINATION |
| ON THE EXTERIOR SIDE OF OUTDOOR ENTRANCES OR EXITS |
| WITH GRADE LEVEL ACCESS. A VEHICLE DOOR IN A GARAGE |
| SHALL NOT |
| BE CONSIDERED AS AN OUTDOOR ENTRANCE OR EXIT |
| |
| |
2015-12-07 18:42:41 | NEW PLANS SUBMITTED. JG. |