Plan Review Notes For Permit 15080721 |
Permit Number |
15080721 |
|
Review Stop |
B |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2015-08-20 12:37:34 | BUILDING PLAN REVIEW | | REVISION: 15080721 | | PERMIT: 14120169 | | ADD: 716 N. SAPODILLA AVE. | | CONT: NUJAK DEV. | | TEL: (561)847-3291 | | | | 2010 FLORIDA BUILDING CODE W | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | 1ST REVIEW | | DATE: THURS. AUAGUST 20/ 2015 | | ACTION: DENIED | | | | 1) THIS REVISION SHOWS THE REMOVAL OF A STEEL ANGLE, | | HOW WILL THE BLOCK ABOVE THE NEW DOOR OPENING BE | | SUPPORTED WITHOUT A LINTEL OR BEAM ABOVE. PLEASE SHOW | | COMPLIANCE WITH THE 2010 FBC-B 2108.2 ACI 530/ASCE 5 | | SHEAR REINFORCEMENT SHALL BE PROVIDED PARALLEL TO THE | | DIRECTION OF APPLIED SHEAR FORCE. SPACING OF SHEAR | | REINFORCEMENT SHALL NOT EXCEED THE LESSER OF D/2 OR 48 | | INCHES. PLEASE SHOW HOW COMPLIANCE WITH THIS SECTION IS | | TO BE ACHIEVED. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | |
|