Date |
Text |
2015-09-01 08:19:50 | ****CORRECTIONS**** |
| |
| SAMANTHA HILL |
| BUILDING PLANS EXAMINER |
| [email protected] |
| 561-805-6724 |
| |
| 1. PROPERTY HAS A VIOLATION ISSUED, BUT NO PERMIT |
| APPLICATION HAS BEEN APPLIED FOR. OWNER HAS ALREADY MET |
| WITH CODE ENFORCEMENT AND IS AWARE OF THE ISSUES. FOR |
| YOUR CONVENIENCE, CODE ENFORCEMENT VIOLATION NOTE: |
| |
| FAILED, MET WITH PROPERTY OWNER BY HIS REQUEST FOR LIEN |
| REDUCTION HEARING. PROPERTY REMAINS IN VIOLATION, NO |
| RENTAL LICENSE, FENCE INSTALLED WITH OUT PERMITS, |
| LANDSCAPING NOT BEING MAINTAINED, OUTDOOR STORAGE, |
| CONVERSION UNDER STAIRS, TREE STUMPS, INOPERABLE |
| VEHICLES ETC. |
| |
| PROVIDE PLANS WHICH INCLUDE ALL WORK INSTALLED WITHOUT |
| PERMIT, PLANS TO LEGALIZE OR REMOVE THIS WORK, FBC 107 |
| (SEE BELOW). |
| |
| 2. FBC 5TH EDITION EXISTING BUILDING 301.1, PLANS |
| SUBMITTED STATE THIS IS A LEVEL ONE ALTERATION. WORK |
| DONE WITHOUT PERMIT WAS NOT ADDRESSED, AND WORK TO BE |
| REMOVED OR MADE LEGAL UNDER A BUILDING PERMIT IS WAS |
| NOT PRESENTED. PLANS STATE THAT ELECTRICAL IS UNDER A |
| SEPARATE PERMIT. SCOPE NOT CLEAR. AFTER ALL WORK IS |
| SHOWN ON A PLAN , THE ALTERATION METHOD WILL BE |
| CONFIRMED. |
| |
| 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS |
| SHALL BE IN ACCORDANCE WITH SECTIONS |
| 107.2.1 THROUGH 107.2.5. |
| 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. |
| CONSTRUCTION DOCUMENTS SHALL BE |
| DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL. |
| ELECTRONIC MEDIA DOCUMENTS SHALL BE |
| SUBMITTED WHEN APPROVED BY THE BUILDING OFFICIAL. |
| CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT |
| CLARITY TO INDICATE THE LOCATION, NATURE AND EXTENT OF |
| THE WORK PROPOSED AND SHOW IN |
| DETAIL THAT IT WILL CONFORM TO THE PROVISIONS OF THIS |
| CODE AND RELEVANT LAWS, ORDINANCES, RULES |
| AND REGULATIONS, AS DETERMINED BY THE BUILDING |
| OFFICIAL. SUCH DRAWINGS AND SPECIFICATIONS SHALL |
| CONTAIN INFORMATION, IN THE FORM OF NOTES OR OTHERWISE, |
| AS TO THE QUALITY OF MATERIALS, WHERE |
| QUALITY IS ESSENTIAL TO CONFORMITY WITH THE TECHNICAL |
| CODES. SUCH INFORMATION SHALL BE SPECIFIC, |
| AND THE TECHNICAL CODES SHALL NOT BE CITED AS A WHOLE |
| OR IN PART, NOR SHALL THE TERM "LEGAL" OR |
| ITS EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC |
| INFORMATION. ALL INFORMATION, DRAWINGS, |
| SPECIFICATIONS AND ACCOMPANYING DATA SHALL BEAR THE |
| NAME AND SIGNATURE OF THE PERSON |
| RESPONSIBLE FOR THE DESIGN. |
| |
| 3. BUILDING CODES LISTED INCLUDES RESIDENTIAL AND |
| BUILDING, ENGINEER TO EXPLAIN HOW THIS IS POSSIBLE. |
| |
| 4. PLANS SUBMITTED SHOW BOLTS ATTACHED TO SLAB, PLEASE |
| CLARIFY THAT THERE IS A CONCRETE SLAB ON THE SECOND |
| FLOOR. IS WORK ONLY ON FIRST FLOOR? SCOPE NOT CLEAR. |
| |
| PLANS SUBMITTED STATE THIS IS A SINGLE FAMILY DWELLING, |
| BUT A VIOLATION HAS BEEN ISSUED WHICH CREATED MULTIPLE |
| UNITS IN THIS STRUCTURE. NO WORK IS SHOWN AS BEING |
| REMOVED. |
| |
| ANOTHER PERMIT WAS APPLIED FOR, DRYWALL AND TILE. UNTIL |
| SCOPE IS CLARIFIED, NO TILE WORK IS TO BE DONE. |
| |
| WHEN MONEY IS OWED TO THE CITY, NO PERMITS SHALL BE |
| ISSUED EXCEPT TO CORRECT VIOLATIONS. CITY OF WEST PALM |
| BEACH MUNICIPAL CODE (WWW.MUNICODE.COM): |
| |
| SEC. 94-10. - FINANCIAL DEBTS AND OBLIGATIONS OWED TO |
| THE CITY. |
| |
| NO APPLICATIONS WILL BE PROCESSED BY THE CITY, AND NO |
| REVIEWS WILL BE CONDUCTED BY THE CITY, UNTIL AN |
| APPLICANT HAS FIRST SHOWN THAT THE APPLICANT IS NOT |
| FINANCIALLY INDEBTED TO THE CITY FOR ANY REASON, |
| INCLUDING, BUT NOT LIMITED TO, AD VALOREM PROPERTY |
| TAXES, SPECIAL ASSESSMENTS, CITY UTILITY CHARGES, AND |
| OTHER GOVERNMENT-IMPOSED LIENS. THIS SECTION DOES NOT |
| APPLY TO THOSE LOANS WITH THE CITY THAT ARE CURRENT IN |
| PAYMENT. FURTHERMORE, THIS SECTION MAY BE WAIVED BY THE |
| CITY UPON A SHOWING BY THE APPLICANT THAT THE REVIEW IS |
| A NECESSARY PREREQUISITE FOR BRINGING A PROPERTY THAT |
| IS OUT OF COMPLIANCE WITH THIS CODE INTO COMPLIANCE |
| WITH THIS CODE. |
| |
| ISSUANCE OF PERMITS FOR NEW WORK TO IMPROVE THE |
| PROPERTY PRIOR TO ISSUANCE OF PERMITS TO CORRECT |
| EXISTING CODE (AND POSSIBLE LIFE SAFETY) VIOLATIONS |
| WILL REQUIRE THE APPROVAL OF THE BUILDING OFFICIAL. AT |
| THIS TIME, NO PERMIT HAS BEEN APPLIED FOR TO CORRECT |
| THE VIOLATION. IT IS ACKNOWLEDGED THAT THE WORK WAS |
| LIKELY DONE BY A PRIOR OWNER. |
| |
| 3. REVISE PLAN TO INCLUDE ROOM DESIGNATIONS AND SHOW |
| COMPLIANCE WITH FBC RESIDENTIAL 310, FBC EXISTING |
| BUILDING 704.1. |
| |
| |
| |