Date |
Text |
2015-08-28 13:41:45 | 1ST REVIEW: FBC 2014 5TH ED. |
| |
| PLEASE PROVIDE SOME KIND OF PLAN AND/OR SCHEDULE FOR |
| DOOR AAND WINDOW REPLACEMENTS. PROVIDE TYPICALLY |
| REQUIRED INFOMATION SUCH AS SIZE TYPE OF WINDOW/DOOR, |
| EXISTING VS PROPOSED CONDITION OPENING LOCATION AND |
| DESIGN PRESSURES PLANNED EGRESS TO DEMONSTRATE CODE |
| COMPLIANCE. |
| |
| NOTE PER FBC - R301.2.1.2 PROTECTION OF OPENINGS. |
| WINDOWS IN BUILDINGS LOCATED IN WINDBORNE DEBRIS |
| REGIONS SHALL HAVE GLAZED OPENINGS PROTECTED FROM |
| WINDBORNE DEBRIS. GLAZED OPENING PROTECTION FOR |
| WINDBORNE DEBRIS SHALL MEET THE REQUIREMENTS OF THE |
| LARGE MISSILE TEST OF ASTM E 1996, ASTM E 1886, SSTD 12 |
| OR TAS 201, 202 AND 203 OR AAMA 506 REFERENCED THEREIN. |
| GARAGE DOOR GLAZED OPENING PROTECTION FOR WINDBORNE |
| DEBRIS SHALL MEET THE REQUIREMENTS OF AN APPROVED |
| IMPACT RESISTING STANDARD OR ANSI/DASMA 115. |
| |
| 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. |
| CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN |
| UPON SUITABLE MATERIAL. ELECTRONIC MEDIA DOCUMENTS |
| SHALL BE SUBMITTED WHEN APPROVED BY THE BUILDING |
| OFFICIAL. CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT |
| CLARITY TO INDICATE THE LOCATION, NATURE AND EXTENT OF |
| THE WORK PROPOSED AND SHOW IN DETAIL THAT IT WILL |
| CONFORM TO THE PROVISIONS OF THIS CODE AND RELEVANT |
| LAWS, ORDINANCES, RULES AND REGULATIONS, AS DETERMINED |
| BY THE BUILDING OFFICIAL. SUCH DRAWINGS AND |
| SPECIFICATIONS SHALL CONTAIN INFORMATION, IN THE FORM |
| OF NOTES OR OTHERWISE, AS TO THE QUALITY OF MATERIALS, |
| WHERE QUALITY IS ESSENTIAL TO CONFORMITY WITH THE |
| TECHNICAL CODES. SUCH INFORMATION SHALL BE SPECIFIC, |
| AND THE TECHNICAL CODES SHALL NOT BE CITED AS A WHOLE |
| OR IN PART, NOR SHALL THE TERM "LEGAL" OR ITS |
| EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC |
| INFORMATION. ALL INFORMATION, DRAWINGS, SPECIFICATIONS |
| AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE |
| OF THE PERSON RESPONSIBLE FOR THE DESIGN. |
| |
| |
| STEVEN KENNEDY, CBO |
| CHIEF PLANS EXAMINER |
| (561) 805-6710 |
| [email protected] |
| |