Date |
Text |
2015-09-28 10:28:54 | PLAN |
| REVIEW COMMENTS |
| |
| 1ST REVIEW: FBC FIFTH EDITION (2014) |
| ROBERT MCDOUGAL, CBO |
| COMMERCIAL COMBINATION PLANS EXAMINER |
| (561) 805-6714 |
| [email protected] |
| |
| DENIED BY BUILDING |
| PLEASE ADDRESS THE ITEMS NOTED BELOW: |
| |
| 1) SUBMIT TWO SETS OF RESIDENTIAL BUILDING FORMS TO |
| SHOW COMPLIANCE WITH 2014 FBC ENERGY CONSERVATION |
| R101.5 |
| |
| 2) THE SIZES OF THE BEAMS SHOWN ON THE PLANS SUPPORTING |
| THE SECOND FLOOR WALLS ARE DIFFERENT ON SHEETS A210 AND |
| S-2. FBC 107.2.1 |
| |
| 3) ON SHEET S-3 THE MARKS FOR SECTIONS 1, 2, 3 AND 4 |
| REFER TO SHEET S-2 AND THE SECTIONS ARE ON SHEET S-6. |
| FBC 107.2.1 |
| |
| 4) SPECIFY THE REQUIRED COMPONENT AND CLADDING DESIGN |
| PRESSURES FOR THE EXTERIOR DOORS AND WINDOWS ON THE |
| PLANS. FBC - R301.2.1 |
| |
| 5) SUBMIT TWO COPIES OF THE EVALUATION REPORTS WITH |
| INSTALLATION INSTRUCTIONS FOR THE SPRAY FOAM |
| INSULATION. FBC - R316 |
| |
| 6) SUBMIT TWO COPIES OF THE MANUFACTURER'S |
| SPECIFICATIONS WITH INSTALLATION INSTRUCTIONS AND |
| LISTING FOR THE IISOKERN FIREPLACE. FBC - R1001 & M1801 |
| |
| 7) FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS |
| FOR THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE 9N-3 |
| THAT HAVE BEEN REVIEWED AND APPROVED IN WRITING BY THE |
| DESIGNER OF RECORD. PROVIDE TWO COMPLETE PRODUCT |
| APPROVALS WITH FL OR NOA NUMBERS INCLUDING INSTALLATION |
| INSTRUCTIONS AND MAXIMUM DESIGN PRESSURES FOR THE CLAY |
| S-TILE ROOFING MATERIAL AND THE ARCH TOP FRONT DOOR. |
| |
| 8) SPECIFY THE SPECIFIC METHOD OF ATTACHMENT THAT WILL |
| BE USED TO INSTALL THE CLAY S-TILE AND RESIST THE |
| REQUIRED OVERTURN MOMENT. IF AN ADHESIVE IS USED SUBMIT |
| THE PRODUCT APPROVALS FOR IT. FBC - R905.3 & DCA RULE |
| 9N-3 |