Plan Review Notes
Plan Review Notes For Permit 15080218
Permit Number 15080218
Review Stop B
Sequence Number 2
Notes
Date Text
2015-10-20 14:32:21****CORRECTIONS****
 REVISED 11/9/15 (SEE NEW COMMENT)
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. OPENING DIMENSIONS AND NOTES UNDER "GENERAL SCOPE OF
 WORK" ARE TOO SMALL TO BE LEGIBLE. INCREASE FONT SIZE
 FOR THESE ITEMS, FBC 107.
  
 2. REVISE THE INSTALLATION SCHEDULE AS FOLLOWS:
  
 A. SHUTTER MOUNTING CONNECTION TYPE SHOULD CORRELATE
 WITH THE ANCHOR CHARTS IN THE PRODUCT APPROVAL; FOR
 EXAMPLE, SEE SHEET 11. SECTIONS (CONNECTION TYPES) ARE
 NAMED 1(TOP), 1(BOTTOM), 2(TOP), 2(BOTTOM), ETC.
  
 B. IF INSTALLATION IS VERTICAL, SPANS SHOULD BE THE
 DIMENSION ANCHOR TO ANCHOR, SO SHOULD BE OPENING HEIGHT
 PLUS EDGE DISTANCE TOP AND BOTTOM. SPANS APPEAR TO
 CORRELATE WITH THE HORIZONTAL DIMENSION, THE WIDTH.
  
 WITHOUT THE CONNECTION TYPE AND SPAN, IT IS NOT
 POSSIBLE TO DETERMINE CODE COMPLIANCE.
  
 3. WHEN RESUBMITTING, REVISE THE APPLICATION TO BE
 CONSISTENT WITH THE SCOPE OF WORK STATED (STILL STATES
 WINDOW AND DOOR REPLACEMENT).
  
 4. WHEN RESUBMITTING, COLLATE TWO IDENTICAL SETS OF
 PERMIT DOCUMENTS FOR PERMIT ISSUANCE.
  
 ***NEW COMMENT***
  
 5. RESUBMITTAL FORM STATES THAT "EXISTING WINDOWS TO
 REMAIN." WINDOWS WERE REPLACED WITHOUT A PERMIT AND
 THEREFORE A CODE CASE WAS GENERATED. THE WINDOWS
 INSTALLED WITHOUT PERMIT REQUIRE A PERMIT. THEY ARE NOT
 CONSIDERED "EXISTING" AS THEY HAVE NOT BEEN PERMITTED
 AND INSPECTED AND THEY DO NOT COMPLY WITH FBC
 REQUIREMENTS (LACKING IMPACT PROTECTION).
  
  
  
  
  
  