Plan Review Notes For Permit 15080157 |
Permit Number |
15080157 |
|
Review Stop |
B |
Sequence Number |
2 |
|
Notes |
Date |
Text |
2015-09-21 16:46:36 | ****CORRECTIONS**** | | | | ART LANGE - BUILDING INSPECTOR | | 561-805-6667 [email protected] | | FBC FLORIDA BUILDING CODE 2014 5TH EDITION/ FRC FLORIDA | | RESIDENTIAL CODE 2015 5TH EDITION | | | | SECOND REVIEW: | | | | 1. ADDRESSED. | | | | 2. FBC - R301.2.1.2 PROTECTION OF OPENINGS. | | WINDOWS IN BUILDINGS LOCATED IN WINDBORNE DEBRIS | | REGIONS SHALL HAVE GLAZED OPENINGS PROTECTED FROM | | WINDBORNE DEBRIS. GLAZED OPENING PROTECTION FOR | | WINDBORNE DEBRIS SHALL MEET THE REQUIREMENTS OF THE | | LARGE MISSILE TEST OF ASTM E 1996, ASTM E 1886, SSTD 12 | | OR TAS 201, 202 AND 203 OR AAMA 506 REFERENCED THEREIN. | | | | 3. PROVIDE TWO COPIES OF A PRODUCT APPROVAL NOA FOR | | WINDOWS USED. IF WINDOWS ARE NOT IMPACT WINDOWS PROVIDE | | SHUTTER SCHEDULE AND NOA'S. | | | | 4. PLEASE SHOW THE ROOM USE OF THE NEW ROOM AND THE | | EXISTING ROOM THAT THE DOORWAY IS GOING TO BE BLOCKED | | OFF. NEW: NOW THAT THE EXISTING ROOM THAT HAS THE DOOR | | BLOCKED OFF IS SHOWN AS A BEDROOM. PLEASE SHOW HOW THIS | | ROOM WILL COMPLY WITH R-310 EMERGENCY ESCAPE AND RESCUE | | OPENINGS. | | | | 5. ADDRESSED | | | | 6. ADDRESSED | | | | 7. ADDRESSED | | | | 8. ADDRESSED | | | | 9. SHOW WALL SHEATHING FASTENING METHOD. | | | | |
|