Plan Review Notes
Plan Review Notes For Permit 15080117
Permit Number 15080117
Review Stop E
Sequence Number 2
Notes
Date Text
2015-11-18 10:24:43APPROVED WITH THE FOLLOWING PROVISOS: ELECTRICAL
 PROVISO FOR PERMIT 15080117
  
 1. RECESSED LIGHTING SHALL COMPLY WITH FBC-E SECTION
 R402.4.4 RECESSED LIGHTING INSTALLED IN BUILDING?S
 THERMAL ENVELOPE SHALL IC RATED AND BE SEALED TO LIMIT
 AIR LEAKAGE BETWEEN CONDITIONED AND NON-CONDITIONED AIR
 SPACE.
 2. THE ADDITION OF AN ATTACHED GARAGE FORCES YOU TO
 COME INTO COMPLIANCE WITH THE FBC-R SECTION 314 & 315.
 YOU SHALL INSTALL INTER-CONNECTED SMOKE DETECTORS
 THROUGH-OUT THE ENTIRE AS IN NEW CONSTRUCTIONS. YOU
 SHALL FURTHER INSTALL A CARBON MONOXIDE DETECTOR WITH
 10? OF THE DOOR TO EACH AREA USED FOR SLEEPING.
  
  