Plan Review Notes For Permit 15070928 |
Permit Number |
15070928 |
|
Review Stop |
E |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2015-08-25 16:43:23 | 1ST REVIEW: FBC 2014 5TH ED. NEC 2011 | | | | FBC- 107.3.5.3 ? PROVIDE EVIDENCE OF EXISTION PERMITTED | | WORK OR PROVIDE A NEW COMPLETE LOAD CALCULATIONS, PANEL | | SCHEDULES AND SHOW CIRCUITS ON FLOOR PLAN. | | | | FBC- 107.3.5.3 ? PROVIDE SMOKE DETECTORS PURSUANT TO | | FBC-R 314.3.1 AS REQUIRED FOR NEW DWELLINGS. | | | | FBC-R 315.1 ? PROVIDE CARBON MONOXIDE ALARMS WITHIN 10 | | FEET OF EACH SLEEPING ROOM. | | | | NEC 210.52(A)(1)&(2) OUTLET SPACING, IT APPEARS SOME | | POINTS ALONG THE WALL EXCEED 6? FROM AN OUTLET | | | | NEC 210.12B - OUTLETS TO BE AFCI PROTECTED. | | | | NEC 406.11- PROVIDE TAMPER RESISTANT RECEPTACLES. | | | | FBC 1006.1 MEANS OF EGRESS ILLUMINATION. | | | | STEVEN KENNEDY, CBO | | CHIEF PLANS EXAMINER | | (561) 805-6710 | | [email protected] | | | | |
|