Plan Review Notes
Plan Review Notes For Permit 15070928
Permit Number 15070928
Review Stop B
Sequence Number 1
Notes
Date Text
2015-08-25 16:07:461ST REVIEW: FBC 2014 5TH ED.
  
 FROM CITY RECORDS, IT CANNOT BE ASCERTAINED THAT THE
 AREA DEPICTED ON THE PLAN SHOWN AS "AS BUILT" AND
 INDICATED AS HABITAL SPACE CONSISTING OF A FAMILY ROOM,
 TWO BEDROOMS, A LIVING ROOM AND LAUNDRY ROOM, WAS
 PREVIOUSLY CONSTRUCTED FOR HABITAL USE WITHIN THE R3
 OCCUPANCY CLASSIFICATION. PERMIT 6365I WAS ISSUED ON
 6/1/1983, I PRESUME THAT IS WHEN THE APPROXIMATELY 650
 SF AREA WAS BUILT. THE PROPERTY APPRAISER WEB SITE
 SHOWS THIS PORTION OF THE STRUCTURE AS "SEMI FINISHED
 BASE AREA."
  
 PLEASE PROVIDE ANY RECORDS YOU MAY HAVE TO DEMONSTRATE
 CONSTRUCTION DETAILS OF THIS PART OF THE STRUCTURE.
 ALTERNATIEVLY, IF THE IMPROVEMENTS ARE AS COMPLETE AS
 THE PLAN INDICATES, PROVIDE THE FOLLOWING:
  
 AN ENERGY SUBMITTAL
  
 FBCE-103.2.1.1.1 BUILDING THERMAL ENVELOPE ALTERNATIVE.
 AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM 402
 SHALL BE SUBMITTED TO THE BUILDING OFFICIAL TO
 DEMONSTRATE CODE COMPLIANCE BY THIS METHOD.
  
 FBCE-103.2.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE.
 AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM 405
 (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE
 SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE
 COMPLIANCE BY SECTION 405.
  
 DETAILS TO DEMONSTRATE PROPOSED OR EXISTING BUILDING
 ENVELOPE THERMAL EFFICIENTCY.
  
 FBC - R301.2.1.2 PROTECTION OF OPENINGS. PROVIDE AN
 IMPACT PROTECTION SUBMITTAL.
 WINDOWS IN BUILDINGS LOCATED IN WINDBORNE DEBRIS
 REGIONS SHALL HAVE GLAZED OPENINGS PROTECTED FROM
 WINDBORNE DEBRIS. GLAZED OPENING PROTECTION FOR
 WINDBORNE DEBRIS SHALL MEET THE REQUIREMENTS OF THE
 LARGE MISSILE TEST OF ASTM E 1996, ASTM E 1886, SSTD 12
 OR TAS 201, 202 AND 203 OR AAMA 506 REFERENCED THEREIN.
  
 ADVISORY COMMENT IF WORK WAS COMPLETED WITHOUT A PERMIT
 PLEASE BE ADVISED THE INSPECTOR MAY REQUIRE PREVIOUSLY
 COMPLETED WORK TO BE MADE ACCESSIBLE AND OPEN FOR
 INSPECTION OR REQUIRE ADDITIONAL DOCUMENTATION FOR ALL
 CONCEALED WORK PREVIOUSLY COMPLETED PURSUANT TO FBC 110
 & FBC 117.
  
 FBC 110.1 GENERAL. CONSTRUCTION OR WORK FOR WHICH A
 PERMIT IS REQUIRED SHALL BE SUBJECT TO INSPECTION BY
 THE BUILDING OFFICIAL AND SUCH CONSTRUCTION OR WORK
 SHALL REMAIN ACCESSIBLE AND EXPOSED FOR INSPECTION
 PURPOSES UNTIL APPROVED.
  
 FBC 117 - THE BUILDING OFFICIAL MAY REQUIRE TESTS OR
 TEST REPORTS AS PROOF OF COMPLIANCE. REQUIRED TESTS ARE
 TO BE MADE AT THE EXPENSE OF THE OWNER, OR AGENT, BY AN
 APPROVED TESTING LABORATORY OR OTHER APPROVED AGENCY.
  
  
 STEVEN KENNEDY, CBO
 CHIEF PLANS EXAMINER
 (561) 805-6710
 [email protected]
  
  