2015-08-10 13:34:25****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC 1609
  
 1. PER APPLICANT (AFTER REVIEW #2), THIS IS A RECOVER
 OVER AN INSULATED STEEL DECK. A MOISTURE SURVEY IS
 REQUIRED TO DETERMINE THAT SUBSTRATE (INSULATION) IS
 SUITABLE FOR RECOVER, FBC 5TH EDITION EXISTING BUILDING
 708.3(1), FBC 1510.3.
  
 IF AN ENGINEER?S STATEMENT THAT THE EXISTING ROOF IS
 SUITABLE FOR RECOVERY IS NOT PROVIDED IN THE MOISTURE
 SURVEY, THIS PERMIT WILL BE ISSUED AT CONTRACTOR?S RISK
 AND A PREINSPECT WILL BE REQUIRED PRIOR TO
 COMMENCEMENT.
  
 PROVIDE INFORMATION REGARDING THE EXISTING FLAT ROOF.
 CONTRACT STATES THAT LOOSE GRAVEL WILL BE REMOVED; IS
 THIS A TAR AND GRAVEL ROOF? IF THIS IS, PROVIDE
 MANUFACTURER?S LETTER THAT A RECOVERY IS SUITABLE FOR
 THIS ROOF.
  
 2 - 3 OK
  
 4. OK - PROVISO, PROVIDE 2014 STATE PRODUCT APPROVAL
 WHEN AVAILABLE FOR FOAM ADHESIVE.
  
 5. COMMENT FROM PREVIOUS LISTS: PROVIDE A ROOF PLAN
 WHICH SHOWS REROOF AREAS AND ROOF RECOVER AREAS.
 INCLUDE ROOF PITCH, ROOF DECK SUBSTRATE TYPE, AND MEAN
 ROOF HEIGHT. THE NOTE (3/12/18/12) IS NOT CLEAR.
 NOT PROVIDED. APPLICANT HAS PROVIDED THE MEAN ROOF
 HEIGHT AND SUBSTRATE FOR THE FLAT ROOF. PLEASE PROVIDE
 A ROOF PLAN SHOWING ROOF AREAS AND ROOF PITCH. ARE
 THERE TWO PITCHED AREAS, 3/12 AND 18/12? APPLICANT CAN
 USE AN AERIAL AND MARK IT UP (PROVIDED THAT IT IS
 LEGIBLE) IF APPLICANT IS UNABLE TO PROVIDE A ROOF PLAN.
 A BUILDING OUTLINE IS AVAILABLE ON PAPA AS WELL:
  
 HTTP://PBCGOV.COM/PAPA/ASPS/PROPERTYDETAIL/STRUCTURALDE
 TAIL.ASPX?ENTITY_ID=74434304150000021&OWNER_NAME=JEROME
 +GOLDEN+CENTER+FOR+BEHAVIORAL
  
 THIS WAS REQUESTED IN PREVIOUS REVIEWS. THIS IS
 REQUIRED TO ASSIST IN DETERMINING THE FOLLOWING:
 BUILDING COVERED UNDER THIS PERMIT (?BUILDING THREE? IS
 AN IDENTIFICATION USED BY THE OWNER, NOT CLEAR WHICH
 BUILDING THIS PERMIT IS FOR, NOT CLEAR HOW THIS NUMBER
 WAS ASSIGNED, WHETHER IT IS CONSISTENT WITH PAPA
 RECORDS), CONFIRM VALUE FBC 109, CONFIRM SCOPE AND
 NATURE OF WORK FBC 107.
  
 IF QUALIFIER HAS ISSUE WITH PROVIDING THIS INFORMATION,
 PLEASE CALL ME TO DISCUSS.
  