Plan Review Notes For Permit 15070848 |
Permit Number |
15070848 |
|
Review Stop |
B |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2015-07-30 15:00:15 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | FBC 1609 | | | | 1. FOR THE FLAT DECK, INDICATE WHICH APPROVED ASSEMBLY | | IS PROPOSED. | | | | 2. FOR THE TILE, INDICATE METHOD OF FASTENING (ON THE | | ADHESIVE PRODUCT APPROVAL). | | | | 3. THE TILE DRAWING WAS PRINTED PORTRAIT ORIENTATION SO | | IS REDUCED AND NOT LEGIBLE. PROVIDE A LEGIBLE DRAWING | | (SHEET 1 OF 1, FL 17330). | | | | 4. THE TILE, TILE ADHESIVE, TILE UNDERLAYMENT PRODUCT | | APPROVALS ARE EXPIRED (2010 RATHER THAN 2014). | | | | 5. PROVIDE A ROOF PLAN WHICH SHOWS REROOF AREAS. | | INCLUDE ROOF PITCH, ROOF DECK SUBSTRATE TYPE, AND MEAN | | ROOF HEIGHT. THE NOTE (3/12/18/12) IS NOT CLEAR. | | | | 6. PROVIDE A COPY OF THE CONTRACT FOR THIS JOB, FBC | | 109. | | | | | | |
|