Plan Review Notes
Plan Review Notes For Permit 15070542
Permit Number 15070542
Review Stop B
Sequence Number 2
Notes
Date Text
2015-09-21 11:17:122ND REVIEW: FBC 2014 5TH ED.
  
 APPARENTLY CHANGES WERE MADE TO THE ORIGINAL PLAN AS A
 FUNCTION OF THE HISTORIC REVIEW AS TO RETAINING THE
 CARRIAGE DOORS. THE CHANGES, ALONG WITH THE ASSOCIATED
 PRODUCT APPROVALS FOR THE WINDOWS AND DOORS MUST BE
 REVIEWED BY THE DESIGNER OF RECORD. STEPHEN GAYDOSH.
 (NOTE, THE RE-SUBMITTED PLAN IS NOT CONSISTENT WITH THE
 PREVIOUS PLAN APPROVED BY THE HISTORIC PLANNER.
  
 INDICATE IF THE BUILDING IS EXEMPT FROM THE
 REQUIREMENTS OF THE FBC ENERGY CONSERVATION. IF NOT,
 PROVIDE EITHER:
  
 FBCE-R101.5.1.1 BUILDING THERMAL ENVELOPE ALTERNATIVE.
 AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R402
 SHALL BE SUBMITTED TO THE BUILDING OFFICIAL TO
 DEMONSTRATE CODE COMPLIANCE BY THIS METHOD.
  
 FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE.
 AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405
 (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE
 SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE
 COMPLIANCE BY SECTION 405.
  
 R303.9 REQUIRED HEATING.
 WHEN THE WINTER DESIGN TEMPERATURE IN TABLE R301.2(1)
 IS BELOW 60?F (16?C), EVERY DWELLING UNIT SHALL BE
 PROVIDED WITH HEATING FACILITIES CAPABLE OF MAINTAINING
 A MINIMUM ROOM TEMPERATURE OF 68?F (20?C) AT A POINT 3
 FEET (914 MM) ABOVE THE FLOOR AND 2 FEET (610 MM) FROM
 EXTERIOR WALLS IN ALL HABITABLE ROOMS AT THE DESIGN
 TEMPERATURE. THE INSTALLATION OF ONE OR MORE PORTABLE
 SPACE HEATERS SHALL NOT BE USED TO ACHIEVE COMPLIANCE
 WITH THIS SECTION.
  
  
 STEVEN KENNEDY, CBO
 CHIEF PLANS EXAMINER
 (561) 805-6710
 [email protected]
  