Date |
Text |
2015-09-09 19:19:30 | RESIDENTIAL (R3) ALTERATION BUILDING REVIEW COMMENTS. |
| CODE: FBC-5TH EDITION (2014). |
| |
| 1- ENGINEER OF RECORD TO UPDATE LICENSE WITH THE |
| FLORIDA DEPARTMENT OF BUSINESS PROFESSIONAL REGULATION |
| (DBPR). CHAPTER 471 F.S. |
| |
| 2- ON JUNE 30TH, 2015 THE NEW CODE TOOK EFFECT. ALL |
| PERMIT APPLICATIONS SUBMITTED ON OR AFTER JUNE 30TH |
| WILL BE REVIEWED UNDER THE FBC-5TH EDITION (2014). |
| REVISE ALL PLANS AND NOTES REFERENCING THE CURRENT |
| CODE. SEC. 553.73 F.S. |
| |
| 3- SPECIFY TYPE AND SIZE OF EXISTING BEDROOM WINDOWS |
| AND TYPE AND SIZE OF PROPOSED WINDOWS TO VERIFY |
| COMPLIANCE WITH THE EGRESS REQUIREMENTS OF SEC. 704 OF |
| FBC-EXISTING BUILDING, 5TH EDITION (2014). |
| |
| 4- PROVIDE SPECIFICATIONS FOR DOOR LEADING FROM GARAGE |
| TO THE LAUNDRY AREA SHOWING COMPLIANCE WITH SEC. |
| R302.5.1, INCLUDING SPECS FOR SELF-CLOSING DEVICE. |
| |
| 5- CLARIFY WHY SUBMITTING NOA 12-0127.08 FOR HORIZONTAL |
| SLIDING WINDOWS. PLANS DON'T SHOW ANY HORIZONTAL |
| SLIDING WINDOW. SEC. 107.2.1 CITY AMENDMENTS. |
| |
| 6- SHEET #3: |
| A) EXTERIOR DOOR BUCK NOTE: SPECIFY THE SPACING OF THE |
| 1/4" X 3-3/4" TAPCONS. SEC. R301. |
| |
| B) GARAGE DOOR BUCK NOTE: SPECIFY HOW MUCH EMBEDMENT IS |
| REQUIRED FOR THE 1/2" WEDGE ANCHORS. SEC. R301. |
| |
| 7- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY |
| FAC 61G20-3.002(33) FOR: |
| A) GARAGE DOORS AS SHOWN ON PLANS. |
| |
| B) SINGLE HUNG WINDOWS. PROVIDE 2 COPIES. ONLY ONE WAS |
| SUBMITTED (NOA 12-0127.16). |
| |
| C) FRENCH DOORS. PROVIDE 2 COPIES. ONLY ONE WAS |
| SUBMITTED (NOA 13-0328.11). |
| |
| D) SLIDING GLASS DOORS. PROVIDE 2 COPIES. ONLY ONE WAS |
| SUBMITTED (NOA 12-1204.12). |
| |
| 8- ENGINEER OF RECORD TO APPROVE IN WRITING (NOT |
| SIGNING AND SEALING) ALL THE PRODUCT APPROVALS AS |
| REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. |
| |
| ****PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH |
| COMMENT TO EXPEDITE THE REVIEW PROCESS. |
| ****PLEASE REMOVE AND REPLACE EACH REVISED DRAWING TO |
| EXPEDITE THE REVIEW PRICESS. SUBMIT OLD COPIES FOR |
| REFERENCE. |
| |
| IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT |
| JULIO GOMEZ |
| COMMERCIAL COMBINATION PLANS EXAMINER |
| DEVELOPMENT SERVICES DEPARTMENT |
| (561)805-6712 |
| [email protected] |