2015-08-02 11:56:081ST REVIEW: FBC 2014 5TH ED. NEC 2011
  
 FBC-107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. ALL
 INFORMATION, DRAWINGS, SPECIFICATIONS AND ACCOMPANYING
 DATA SHALL BEAR THE NAME AND SIGNATURE OF THE PERSON
 RESPONSIBLE FOR THE DESIGN.
  
 FBC 107.3.5.3 PROVIDE A CIRCUITING PLAN OR NOTES UPON
 THE PLAN TO DEMONSTRATE THE FOLLOWING. WIRE SIZE,
 WIRING METHOD, OCP.
  
 FBC-R 315.1 ? PROVIDE CARBON MONOXIDE ALARMS WITHIN 10
 FEET OF EACH SLEEPING ROOM, IF APPLICABLE.
  
 FBC- 107.3.5.3 ? PROVIDE SMOKE DETECTORS PURSUANT TO
 FBC-R 314.3.1 AS REQUIRED FOR NEW DWELLINGS.
  
 NEC 406.11- PROVIDE TAMPER RESISTANT RECEPTACLES.
  
 NEC 210.12B - OUTLETS TO BE AFCI PROTECTED.
  
 NEC 210 - PROVIDE GFCI PROTECTED OUTLET ON BATHROOM.
  