Plan Review Notes
Plan Review Notes For Permit 15070272
Permit Number 15070272
Review Stop ENG
Sequence Number 1
Notes
Date Text
2015-09-02 08:43:271. WORK WITHIN RIGHT OF WAY TO COMPLY WITH CITY
 STANDARD DETAILS GC-1 AND GC-6. HTTP://WPB.ORG/ENGINEER
 ING/ENGINEERING-SERVICES/ENGINEERING-STANDARDS/
  
 2. SIDEWALKS SHALL BE OF PORTLAND CEMENT CONCRETE, A
 MINIMUM OF 3,000 PSI, FOUR INCHES (4") THICK, AND FIVE
 FEET (5.0') WIDE. SIDEWALKS SHALL EXTEND ACROSS
 DRIVEWAYS, AT WHICH LOCATIONS THEY SHALL HAVE A MINIMUM
 THICKNESS OF 6" AND BE REINFORCED WITH FIBERMESH. ANY
 NECESSARY OBSTRUCTION SHALL BE PLACED SO AS TO MAINTAIN
 THE MAXIMUM CLEAR WIDTH AND MEET THE REQUIREMENTS OF
 THE AMERICANS WITH DISABILITIES ACT. SIDEWALKS SHALL BE
 MAINTAINED BY THE CITY. THE ABUTTING PROPERTIES SHALL
 MAINTAIN DRIVEWAYS, INCLUDING THE SIDEWALK SECTIONS.
  
 3. MAINTENANCE OF TRAFFIC PLAN (MOT) FOR SIDEWALK
 CLOSURE MUST BE APPROVED BY CITY.
  
 4. SIDEWALKS SHALL HAVE A TRANSVERSE SLOPE OF 2% PER
 FOOT DOWN TOWARD THE SWALE OR GUTTER AND SHALL BE GIVEN
 TRANSVERSE BROOM FINISH. SPECIAL SURFACE TREATMENTS
 SUCH AS PAVERS, TILE, ETC., AND PAINT ARE NOT
 PERMITTED..
  
 5. ALL CONCRETE PLACED WITHIN RIGHT-OF-WAY MUST BE FROM
 A CONCRETE MIX PLANT. BATCH TICKETS ARE TO BE SUBMITTED
 TO CITY INSPECTOR. NO BAG CONCRETE IS AUTHORIZED FOR
 USE WITHIN THE RIGHT OF WAY.
  
 6. WHEN THE REMOVAL OF SIDEWALKS, CURBS OR GUTTERS IS
 NECESSARY FOR CONSTRUCTION, THEY SHALL BE REMOVED IN
 FULL SECTIONS OR A MINIMUM OF FIVE FEET IN LENGTH, AND
 ALL BROKEN EDGES CUT SMOOTH BY USE OF A SUITABLE POWER
 SAW OR OTHER APPROPRIATE MEANS.
  
  
 KELLY CRANFORD, P.E.
 LAND DEVELOPMENT ENGINEER
 PUBLIC WORKS DEPARTMENT
 CITY OF WEST PALM BEACH
 [email protected]
 561-494-1098 (OFFICE)
  


Account Summary | Usage Policy | Privacy Policy