2015-08-06 15:00:58 | ZONING PLAN REVIEW |
| ___________________________________________ |
| |
| DATE OF REVIEW: 08.06.2015 |
| PERMIT NO.: 15070093 |
| ADDRESS: 5483 LEEPER DRIVE |
| CONTRACTOR/CONTACT: NICK KAMINSKI |
| TELEPHONE NO.: 561.547.0027 |
| SCOPE OF REVIEW: SITE LIGHTING. |
| ___________________________________________ |
| |
| REVIEW STATUS: FAILED |
| ___________________________________________ |
| |
| PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN |
| REVIEW COMMENTS: |
| |
| 1. PURSUANT TO SECTION 94-207(D)(8) OF THE CITY?S |
| ZONING AND LAND DEVELOPMENT REGULATIONS (ZLDRS), |
| ILLUMINATION SHALL NOT EXCEED 1.0 FOOTCANDLES AT THE |
| PROPERTY LINE. IT APPEARS THAT THIS IS EXCEEDED AT THE |
| ENTRANCE DRIVE. PLEASE EXTEND THE LEVELS TO THE |
| PROPERTY LINE AT THE CUL-DE-SAC, AND ENSURE THAT THEY |
| DON'T EXCEED 1.0. |
| |
| 2. THE POLE DETAIL SHOWN ON SHEET PH1.00 DIFFERS FROM |
| THAT PROVIDED IN THE STRUCTURAL ANALYSIS. THE POLE |
| DETAIL ON SHEET PH1.00 IS AN ALUMINUM POLE. THE POLE |
| DETAIL ATTACHED TO THE ENGINEERS REPORT IS FOR A |
| CONCRETE POLE. |
| |
| 3. THE POLE DETAIL SHOWN ON SHEET PH1.00 REFERENCES A |
| 25 FOOT HIGH POLE; HOWEVER, IT DOES NOT APPEAR THAT |
| THIS POLE HEIGHT IS BEING USED. IT IS NOT REFERENCED IN |
| LUMINAIRE SCHEDULE, ETC. PLEASE CLARIFY. |
| ___________________________________________ |
| |
| PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| ___________________________________________ |
| |
| QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: |
| |
| JOHN P. ROACH, AICP, PRINCIPAL PLANNER |
| CITY OF WEST PALM BEACH |
| DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION |
| 401 CLEMATIS STREET - P.O. BOX 3147 |
| WEST PALM BEACH, FLORIDA 33402 |
| |
| P: 561.822.1448 |
| F: 561.822.1460 |
| |
| E: [email protected] |
| |
| WWW.WPB.ORG |
| |