Plan Review Notes For Permit 15060923 |
Permit Number |
15060923 |
|
Review Stop |
B |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2015-08-20 18:50:48 | PLAN | | REVIEW COMMENTS | | | | 1ST REVIEW: FBC 2010 | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) SHOW COMPLIANCE WITH FBC EXISTING BUILDING 604.1 FOR | | EGRESS WINDOWS IN THE SECOND FLOOR BEDROOM. THE | | EXISTING 30" X 36" BEDROOM WINDOWS WERE JALOSIE WINDOWS | | WHICH WOULD ALLOW THE SLATS TO BE REMOVED OR EASILY | | BROKEN OUT IN AN EMERGENCY. THE PROPOSED IMPACT RATED | | SINGLE HUNG WINDOWS WILL NOT PROVIDE A LARGE ENOUGH | | CLEAR OPENING AND WOULD BE VERY DIFFICULT TO BREAK. I | | WOULD SUGGEST THAT YOU CONSIDER INSTALLING A CASEMENT | | WINDOW IN THE BEDROOM. |
|