2015-06-20 02:43:481) SUBMIT TWO COPIES OF THE MANUFACTURER'S
 SPECIFICATIONS FOR REVIEW. ALL EQUIPMENT SHALL BE
 LISTED AND LABELED PER THE 2010 FBC-RESIDENTIAL, SEC.
 G2404.3, WPB AMEND. TO 2010 FBC SEC. 107.1.
 2) SUBMIT TWO COPIES OF THE APPLICABLE SIZING TABLES
 THAT ARE USED FOR THE SIZING OF THE GAS LINE. 2010
 FBC-RESIDENTIAL, SEC. G2413.3.
 3) ONE COPY OF THE PLANS IS DONE IN PENCIL. PLANS IN
 PENCIL ARE UNACCEPTABLE.
 4) INDICATE THE PSI OF THE SYSTEM. IF IT IS A HYBRID
 PRESSURE SYSTEM, SHOW WHERE THE PRESSURE REGULATOR IS
 LOCATED ON THE PLAN. WPB AMEND. TO 2010 FBC SEC.
 107.2.1.
 5) SUBMIT A DETAIL OF THE VENT FOR THE APPLIANCE. SHOW
 THE SIZE OF THE VENT. THE VENT TERMINATION LOCATION
 SHALL BE INSTALLED PER THE MANUFACTURER'S INSTALLATION
 INSTRUCTIONS IF THIS IS A DDIRECT VENT APPLIANCE.
 6) IF YOU ARE ALSO DOING THE WATER PIPING SUBMIT A
 WATER RISER FOR THE COLD & HOT WATER LINES AND SHOW THE
 TYPE OF PIPE & SIZES AND THE SOURCE OF THE WATER
 SUPPLY. INCLUDE THIS UNDER THE DESCRIPTION OF WORK ON
 THE APPLICATION.WPB AMEND. TO 2010 FBC SEC. 107.3.5.3.
  