2015-09-03 14:49:12 | MALBARRAN'S DESK |
2015-09-03 10:36:15 | BUILDING PLAN REVIEW |
| W. P. B. PERMIT: 15060725 |
| ADD: 222 LAKEVIEW AVE. |
| CONT: FASTRACK |
| TEL: (561)304-7881 |
| E-MAIL: [email protected] |
| |
| 2010 FLORIDA BUILDING CODE W |
| * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| |
| 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| OF THE FLORIDA BUILDING CODE, BUILDING. |
| |
| 1ST REVIEW |
| DATE: TUES. JULY 07/ 2015 |
| ACTION: BUILDING PROVISO |
| BUILDING APPROVED WITH EXCEPTION! |
| THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO |
| CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO |
| INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE |
| ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE |
| ADDITIONAL REVIEWS WITH ASSOCIATED FEES. |
| |
| 1) SHEET A2.1 DETAIL J10 ELEVATION & A3.1 DETAIL E14 |
| THE HEADER OVER GARAGE DOOR OPENINGS NEEDS TO SHOW |
| COMPLIANCE WITH 2010 FBC-B |
| 2104.1 MASONRY CONSTRUCTION. MASONRY CONSTRUCTION SHALL |
| COMPLY WITH THE REQUIREMENTS OF SECTIONS 2104.1.1 |
| THROUGH 2104.4 AND WITH TMS 602/ACI 530.1/ASCE 6. |
| ACI 530.1 SECTION 7.5.3.1 SHEAR REINFORCEMENT (STIRRUPS |
| OR HAIRPINS) SHALL BE PROVIDED PARALLEL TO THE |
| DIRECTION OF APPLIED SHEAR FORCE. SPACING OF THE SHEAR |
| REINFORCEMENT SHALL NOT EXCEED THE LESSER OF D/2 OR 48 |
| INCHES. D- BOTTOM STEEL TO TOP OF BEAM. |
| |
| JAMES A. WITMER CBO |
| SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| TEL: 561-805-6715 |
| FAX: 561-805-6676 |
| E-MAIL: [email protected] |
| |
| |
| |