2015-06-22 14:07:41 | |
| ****CORRECTIONS**** |
| ART LANGE - BUILDING INSPECTOR |
| 561-805-6667 [email protected] |
| FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL |
| |
| 1. PLEASE PROVIDE TWO LEGIBLE SETS OF PLANS. 107.2.1 |
| INFORMATION ON CONSTRUCTION DOCUMENTS. CONSTRUCTION |
| DOCUMENTS SHALL BE DIMENSIONED AND DRAWN UPON SUITABLE |
| MATERIAL. CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT |
| CLARITY TO INDICATE THE LOCATION, NATURE AND EXTENT OF |
| THE WORK PROPOSED AND SHOW IN DETAIL THAT IT WILL |
| CONFORM TO THE PROVISIONS OF THIS CODE AND RELEVANT |
| LAWS, ORDINANCES, RULES AND REGULATIONS, AS DETERMINED |
| BY THE BUILDING OFFICIAL. SUCH DRAWINGS AND |
| SPECIFICATIONS SHALL CONTAIN INFORMATION, IN THE FORM |
| OF NOTES OR OTHERWISE, AS TO THE QUALITY OF MATERIALS, |
| WHERE QUALITY IS ESSENTIAL TO CONFORMITY WITH THE |
| TECHNICAL CODES. SUCH INFORMATION SHALL BE SPECIFIC, |
| AND THE TECHNICAL CODES SHALL NOT BE CITED AS A WHOLE |
| OR IN PART, NOR SHALL THE TERM "LEGAL" OR ITS |
| EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC |
| INFORMATION. |
| |
| FBC 107.2.1.4 QUALITY OF BUILDING PLANS. BUILDING PLANS |
| SHALL BE DRAWN TO A MINIMUM 1/8 INCH SCALE UPON |
| SUBSTANTIAL PAPER, CLOTH OR OTHER ACCEPTABLE MEDIUM. |
| THIS POLICY MAY INCLUDE SUCH THINGS AS MINIMUM SIZE, |
| SHAPE, CONTRAST, CLARITY, OR OTHER ITEMS RELATED TO |
| RECORDS MANAGEMENT. |
| |
| 2. PROVIDE CLEAR DETAILS OF ALL CONNECTIONS INCLUDING |
| FASTENER SIZING, SPACING AND EDGE DISTANCE. MANY OF THE |
| MEMBERS ARE NOT LABELED OR NOT LEGIBLE. PROVIDE CLEAR |
| DETAILS FOR UPRIGHT TO CONCRETE CONNECTIONS. SLAB |
| DETAILS, UPRIGHT TO BEAM CONNECTIONS, PURLIN TO BEAM OR |
| POST DETAILS AND SLOPED PURLIN CONNECTION DETAILS, |
| GUTTER ATTACHMENT DETAILS AND DETAILS OF ROOF BRACING |
| AND CABLE CONNECTIONS IF USED. |
| |
| |