2015-07-10 14:29:56 | RESIDENTIAL (R3) RE-ROOF, THIRD BUILDING REVIEW | | COMMENTS. | | CODE: 2010 FBC-RESIDENTIAL. | | | | ****ORIGINAL COMMENT: | | 1- NEW COMMENT TO VERIFY COMPLIANCE WITH THE DESIGN | | PRESSURES OF SEC. R301 OF 2010- FBC-RESIDENTIAL: | | TU PLUS UNDERLAYMENT SUBMITTED: NEED TO IDENTIFY | | UNDERLAYMENT WITH DESIGN PRESSURES THAT MEET THE DESIGN | | PRESSURES FOR ALL ROOF ZONES, INCLUDING THE CORNER | | AREAS. NOTE: THIS HOUSE IS LOCATED IN EXPOSURE "C". THE | | REQUIRED DESIGN PRESSURES FOR CORNER AREAS IS -95.12 | | PSF. | | | | ***NO ASDDRESSED. | | INFORMATION SUBMITTED WAS FLORIDA PRODUCT APPROVAL | | FL7473-R6. THIS IS A ROOF TILE PRODUCT APPROVAL NOT | | UNDERLAYMENT. MY ORIGINAL COMMENT WAS FOR FLORIDA | | PRODUCT APPROVAL UNDERLAYMENT SUBMITTED, NOT THE ROOF | | TILE. SEE ORIGINAL COMMENT ABOVE. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | (561)805-6712 | | [email protected] | | | | | | |
|