Plan Review Notes For Permit 15050732 |
Permit Number |
15050732 |
|
Review Stop |
P |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2015-06-09 09:28:01 | 1) SUBMIT A WATER RISER FOR REVIEW. WPB AMEND. TO 2010 | | FBC SEC. 107.3.5.1.3. | | 2) THE WASHING MACHINE SHALL BE ON A 3 INCH STACK PER | | THE 2010 FPC SEC.406.3. | | 3) SUBMIT MANUFACTURER'S SPECIFICATIONS/INSTALLATION | | MANUAL FOR THE TANKLESS WATER HEATER. WPB AMEND.TO 2010 | | FBC SEC. 107.2.1. | | 4) CLEANOUTS ARE REQUIRED IN WASTE STACKS PER 2010 FPC | | SEC.708.3.4. | | 5) THE SINK IN THE BREAK ROOM SHALL COMPLY WITH THE FL. | | ACCESS. CODE SEC. 212, 606.1- 606.5. THE MAXIMUM HEIGHT | | SHALL BE 34 INCHES. SHOW THIS ON BOTH SETS OF PLANS. | | 6) SHT. S-1 SHOWS THE OCCUPANCY TYPE AS MERCANTILE AND | | THE GENERAL BUILDING CODE ANALYSIS BOX ON E-1 NOTES THE | | OCCUPANCY AS BUSINESS.CLARIFY. ALSO, THE BOX ON SHT. | | E-1 DOES NOT APPEAR TO BE FOR THIS SPACE. THE TENANT | | SPACE IS LISTED AS 6300 SQ.FT. AND SHT. S-1 NOTES THIS | | SPACE AS 1300 SQ. FT.THERE IS ALSO A DIS | | 7) THIS OCCUPANCY SHALL BE CLASSIFIED PER SEC. 302 OF | | THE 2010 - FBC-BUILDING.INDICATE THE CORRECT OCCUPANCY | | ON BOTH SHEETS OF BOTH SETS OF PLANS. | | 8) THERE IS ALSO A DISCREPANCY IN THE TYPE OF | | CONSTRUCTION ON THE PLANS.SHT. S-1 NOTES THE TYPE OF | | CONSTRUCTION AS TYPE III (ZONING 7 OCCUPANCY BOX) & AS | | TYPE IIB (CODE INFORMATION BOX) AND AS TYPE IIB ON SHT. | | E-1. CLARIFY. | | | | PLUMBING PLAN REVIEW | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | 561-805-6692 | | [email protected] | | |
|