Plan Review Notes
Plan Review Notes For Permit 15050499
Permit Number 15050499
Review Stop P
Sequence Number 1
Notes
Date Text
2015-06-14 06:05:311) THE SUBMITTED PLANS SHOW THE EXISTING SPACE BEING
 CONVERTED INTO TWO SEPARATE UNITS. INDICATE THE TYPE OF
 OCUPANCY OF THE SPACES PER THE 2010 FBC SEC.303.
 ADDITIONAL PLUMBING FIXTURES MAY BE REQUIRED PER TABLE
 403.1 OF 2010 FBC-PLUMBING.
 2) INDICATE THE SQUARE FOOTAGE AND OCCUPANT LOAD OF
 BOTH SPACES ON THE PLANS. 2010 FBC SEC. 107.2.1.
 107.3.5.1.
 3) ELEVATION # 3 SHOWS THE WATER CLOSET LOCATED AT
 1'-8" FROM THE REAR WALL TO THE CENTERLINE OF THE WATER
 CLOSET. COMPLY W/ 2010 FBC-ACCESSIBILITY CODE
 SEC.604.2.
 4) THE INSTALLATION OF THE REAR GRAB BAR SHALL COMPLY
 WITH 2010 FBC SEC.604.5.2.
 5) THE LOCATION OF THE TOILET PAPER DISPENSER SHALL
 COMPLY WITH FAC SEC. 604.7.
 6) THE HEIGHT OF THE GRAB BARS SHALL BE INSTALLED IN
 ACCORDANCE WITH 2010 FAC SEC.609.4. THE HEIGHT SHALL BE
 MEASURED TO THE TOP OF THE GRIPPING SURFACE.
 7) SHOW THE CLEAR FLOOR SPACE FOR THE WATER CLOSET AND
 LAVATORY ON THE FLOOR PLAN. CLEAR FLOOR SPACES SHALL
 COMPLY WITH 2010 FAC SEC.604.3 & SEC.305.3.
 8) DOORS SHALL NOT SWING INTO THE CLEAR FLOOR SPACE OR
 ANY FIXTURE PER FAC SEC. 603.2.3.( SEE EXCEPTIONS)
 9) SUBMIT A SANITARY AND WATER RISER DIAGRAM FOR THE
 CHANGES BEING MADE TO THE PLUMBING SYSTEM. WPB AMEND.
 TO 2010 FBC SEC. 107.2.1.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  