2015-08-24 16:20:31BUILDING PLAN REVIEW
 W. P. B. PERMIT: 15050177
 ADD: 1152 OKEECHOBEE RD
 CONT: ABACOA CONSTRUCTION
 TEL: (561)722-3890
 E-MAIL: [email protected]
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 3RD REVIEW
 DATE: WEDNESDAY JULY 22/ 2015
 ACTION: DENIED
  
 1-3) COMPLIED.
  
 4) THE RAISED PLATFORM 20 INCHES ABOVE THE FLOOR DOES
 INDICATE VERTICAL ACCESSIBILITY WILL BE ACHIEVED BY A
 RAMP. THE PLANS INDICATE 20 FEET OF RUN, BUT THERE IS A
 LANDING AT THE TOP OF THE RAMP WHERE A 90 DEGREE TURN
 MUST BE MADE. PLEASE SHOW COMPLIANCE WITH:
  
 4A) 2010 FBC-ACCESSIBILITY 405.7.4 CHANGE IN DIRECTION.
 RAMPS THAT CHANGE DIRECTION BETWEEN RUNS AT LANDINGS
 SHALL HAVE A CLEAR LANDING 60 INCHES (1525 MM) MINIMUM
 BY 60 INCHES (1525 MM) MINIMUM.
  
 4B) ACCESSIBILITY 405.8 HANDRAILS. RAMP RUNS WITH A
 RISE GREATER THAN 6 INCHES (150 MM) SHALL HAVE
 HANDRAILS COMPLYING WITH 505.
 505.3 CONTINUITY.
 HANDRAILS SHALL BE CONTINUOUS WITHIN THE FULL LENGTH OF
 EACH STAIR FLIGHT OR RAMP RUN. INSIDE HANDRAILS ON
 SWITCHBACK OR DOGLEG STAIRS AND RAMPS SHALL BE
 CONTINUOUS BETWEEN FLIGHTS OR RUNS.
  
 505.4 HEIGHT. TOP OF GRIPPING SURFACES OF HANDRAILS
 SHALL BE 34 INCHES (865 MM) MINIMUM AND 38 INCHES (965
 MM) MAXIMUM VERTICALLY ABOVE WALKING SURFACES, STAIR
 NOSINGS, AND RAMP SURFACES. HANDRAILS SHALL BE AT A
 CONSISTENT HEIGHT ABOVE WALKING SURFACES, STAIR
 NOSINGS, AND RAMP SURFACES.
  
 4C) 405.9 EDGE PROTECTION. EDGE PROTECTION COMPLYING
 WITH 405.9.1 OR 405.9.2 SHALL BE PROVIDED ON EACH SIDE
 OF RAMP RUNS AND AT EACH SIDE OF RAMP LANDINGS.
  
  
 5-9) COMPLIED.
  
 10) THE MECHANICAL PLANS ALSO SHOW WALL LOUVERS AND
 ROOF TOP A/C STANDS. PLEASE PROVIDE COMPLIANCE WITH:
 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS,
 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA DEPARTMENT
 OF COMMUNITY AFFAIRS RULE 9N-3 NOV. 01/ 2010 (31)
 SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION SYSTEMS THAT
 WILL REQUIRE PRODUCT APPROVALS:
 (31)(C) WALL LOUVERS
 (G) PRE-ENGINEERED A/C STANDS
  
 11) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE
 PRODUCTS WHICH ARE REGULATED BY THE DCA RULE 9N-03
 SHALL BE REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR
 JURISDICTIONAL APPROVAL.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC
  
 12 ) WHEN RESUBMITTING PLANS PLEASE INDICATE THE
 REVISION & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES
 AS NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  