Plan Review Notes For Permit 15050172
Permit Number 15050172
Review Stop B
Sequence Number 1
Notes
Date Text
2015-06-13 09:23:30REVISION REQUIRED.
 SUBMIT TWO SETS OF PLANS SHOWING THE SIZE AND LOCATION
 OF THE FLOOD OPENINGS.
  
 APPROVED WITH EXCEPTION. THIS PLAN HAS BEEN APPROVED
 PROVISIONALLY. FAILURE TO CORRECT THE LISTED
 DEFICIENCIES IN THIS PLAN PRIOR TO INSPECTION WILL
 RESULT IN FAILED INSPECTION(S) AND ASSESSMENT OF
 RE-INSPECTION FEE(S).
 FBC R322.2.2 (2)(2.1) THERE SHALL BE A MINIMUM OF TWO
 FLOOD OPENINGS ON DIFFERENT SIDES OF EACH ENCLOSED
 AREA: IF A BUILDING HAS MORE THAN ONE ENCLOSED AREA
 BELOW THE DESIGN FLOOD ELEVATION, EACH AREA SHALL HAVE
 OPENINGS ON EXTERIOR WALLS.
  
  
  