 BUILDING PLAN REVIEW
 W. P. B. PERMIT: 15041142
 ADD: 705 N. OLIVE AVE.
 CONT: TBD
 TEL: ( 561)805-6715
 E-MAIL:
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: FRI. MAY 15/ 2015
 ACTION: DENIED
  
 1) DISCREPANCY IN ADDRESSING OF THE PROPERTY. THE
 PERMIT APPLICATION INDICATES THE ADDRESS TO BE 705 N.
 OLIVE AVE. PERMIT: 14030096 IS A 8 LEVEL BUILDING,
 LOFTIN PLACE. THE PLANS SUBMITTED SHOW THE PROPERTY IN
 QUESTION ON THE CORNER OF EUCALYPTUS ST. AND N. DIXIE
 HWY. THE PROPERTY APPRAISER HAS THIS PROPERTY'S ADDRESS
 AS
 375 EUCALYPTUS ST. THE 3RD PHASE OF THE OVER-ALL
 PROJECT.
  
 2) SHEET A.0 TEMPORARY LEASING OFFICE DOES NOT SHOW
 WHERE THE PROPERTY LINE IS LOCATED, IT CAN NOT BE
 DETERMINED IF THE FRONT ENTRY DOOR CROSSES OVER THE
 PROPERTY LINE. PLEASE SHOW COMPLIANCE WITH 2010 FBC-B
 3202.2 ENCROACHMENTS ABOVE GRADE AND BELOW 8 FEET IN
 HEIGHT. DOORS AND WINDOWS SHALL NOT OPEN OR PROJECT
 INTO THE PUBLIC RIGHT-OF-WAY.
  
 3) SHEET A.0 INDICATES TO THE EAST A CLEAR DRIVEWAY OF
 20 FT. PLEASE BE AWARE THE CONSTRUCTION TRAILERS ARE
 JUST TO THE EAST OF THE DRIVEWAY. ONE OF THE CONDITIONS
 THAT THE FIRE DEPARTMENT PUT ON THE PLACEMENT OF THE
 CONSTRUCTION TRAILERS WAS COMPLIANCE WITH NFPA 251 WITH
 60 FEET OF EXPOSED SIDE O FTHE TRAILER THEY WOULD BE
 REQUIRED TO BE 50 FEET AWAY FROM BUILDINGS. AN
 AGREEMENT WAAS MET THAT KAST COULD LEAVE THEIR
 CONSTRUCTION TRAILER WHERE IT WAS IF THE BUILDING TO
 THE WEST WAS LEFT UNOCCUPIED. NOW IT WOULD APPEAR THAT
 EITHER THE BUILDING REMAIN UNOCCUPIED OR KAST
 CONSTRUCTION TRAILER BE MOVED EAST TO COMPLY WITH NFPA
 251.
  
 4) SHEETS A1 & A2 BOTH SHOW THE EXISTING WINDOWS TO BE
 BLOCKED IN, THERE IS NO INFORMATION AS TO HOW THE NEW
 INFILL WILL BE TIED TO THE EXISTING BLOCKWORK.
 2010 FBC-B 2104.1.3 INSTALLATION OF WALL TIES. WALL
 TIES SHALL BE INSTALLED IN ACCORDANCE WITH TMS 602/ACI
 530.1/ASCE 6.
  
 5) BOTH SHEETS A1 & A2 BOTH INDICATE A NEW WIDER FRONT
 ENTRY DOOR PLEASE PROVIDE THE WIND DESIGN CRETERIA;
 WIND DESIGN CRITERIA
 2010 FBC-B 1609.1.1 DETERMINATION OF WIND DESIGN-
 CHAPTER 6 OF ASCE 7-10.
 1609.3 BASIC WIND SPEED FIGURE 1609.A-C
 1609.3 WIND SPEED CONVERSION
  
 5.1) THE BASIC WIND SPEED, VU, SHALL BE DETERMINED IN
 ACCORDANCE WITH 1609.3.1 & ASCE 7-10
  
 5.2) AN IMPORTANCE FACTOR, FIGURE 1609 A-C, ASCE 7-10.
  
 5.3) AN EXPOSURE CATEGORY SHALL BE DETERMINED IN
 ACCORDANCE WITH 1609.4 & ASCE 7-10
  
 5.4) A HEIGHT AND EXPOSURE ADJUSTMENT COEFFICIENT, *
 SHALL BE DETERMINED FROM TABLE 1609.7.2. ASCE 7-10.
  
 5.5) COMPONENTS & CLADDING PRESSURES POSITIVE &
 NEGATIVE TABLE 1609.2(2) .
  
 6) COMPONENTS & CLADDING 2010 FBC-B 1609.1.2 PROTECTION
 OF OPENINGS, 1609.6.4.41 COMPONENTS & CLADDING. FLORIDA
 DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. 01/ 2010
 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION SYSTEMS
 THAT WILL REQUIRE PRODUCT APPROVALS:
 (31)(A) EXTERIOR DOORS
 (B) WINDOW
 (C) MULLION
 7) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS
 WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC..
  
 8) NOTES FROM THE COVERSHEET INDICATE THE EXISITNG DOOR
 OPENING FOUND ON SHEET A1 WILL BE WIDENED FOR A NEW
 STOREFRONT DOOR AND SIDELITE. THE PLANS SHEET A3 DOOR
 SCHEDULE INDICATE THE DOOR TO BE A 3'-0"X 7'-0" WITH A
 2'-0" SIDELITE. THE PLANS DO NOT PROVIDE THE REQUIRED
 WIDTH FOR THE ROUGH OPENING, NOR DO WE KNOW IF THE DOOR
 AND SIDELIGHT ARE TO BE MANUFACTERED A SINGLE UNIT OR
 IF THEY ARE GOING TO BE (2) INDEPENT UNITS REQUIRING A
 MULLOIN. 107.2.1.3 ADDITIONAL INFORMATION IS REQUIRED.
  
 9) SHEET A1 THE FRONT ENTRY DOES HAVE A NOTE THAT THE
 NEW STOREFRONT ENTRY TO HAVE FILED CELL WITH #5 REBAR
 IN CELLS. THE PLANS ARE DEFICIENT IN HOW THE REBAR ARE
 TO CONNENT WITH THE FOOTING AND CONCRETE BEAM ABOVE TO
 FORM PART OF THE MWFRS MAIN WIND FORCE RESISTING
 SYSSTEM.
  
 10) SHEET A2 THE WEST ELEVATION SHOWS THE NEW PROPOSED
 ENTRY DOORWAY. SHEET A3 FOR THE FRONT ENTRY DOOR, DOOR
 # 1 AS A 3'-0"X 7'-0" DOOR WHERE AS IN THE ELEVATION IT
 IS DRARN AS A 8'-0" HIGH DOOR, PLEASE INDICATE IS THERE
 TO BE A NEW BEAM TO HOLD THE BLOCK IN PLACE OR WILL A
 LINTEL BE USED IN THIS APPLICATION? AGAIN ADDITIONAL
 INFORMATION IS REQUIRED. 107.2.1.3. 1609.1.4 MWFRS.
  
 11) SHEET A2 INDICATES A VERTICAL A/C CLOSET WITH A
 DOOR LABELED # 2 FOR ACCESS TO THE UNIT. SHEET A3 THE
 DOOR SCHEDULE DOOR # 2 IS A HOLLOW METAL DOOR WHERE AS
 WHEN YOU LOOK AT SHEET M1 THIS DOOR IS A LOUVERED DOOR.
 DISCREPANCY IN PLANS. 107.2.1.3 PLEASE NOTE THIS UNIT
 BEING A PLENUM RETURN, THERE CAN BE NO COMBUSTIBLES IN
 THE PLENUM, IF A LOUVERED DOOR IS TO BE USED IT MUST BE
 METAL. SEE 2010 FBC-M 602.2.1. MATERIALS WITHIN
 PLENUMS.
  
 12) SHEET A2.1 SHOWS THE USE OF DROPPED CEILINGS AND
 SOFFITS BUT THERE IS NO ATTACHMENT NOR FRAMING DESIGN
 PROVIDED, TYPE OF FRAMING, SPACING OF FRAMING,
 ALLOWABLE SPANS FOR THE FRAMING MEMBERS, IF SSTIFF
 BACKS ARE REQUIRED, NOR THE ALLOWABLE DEFLECTION AS
 WELL AS THE THICKNESS OF THE FINISHING MATERIALS. 2010
 FBC-B TABLE 2508.1. STEEL FRAMING FOR GYPSUM BOARD.
  
 13) WHEN RESUBMITTING PLANS PLEASE INDICATE THE
 REVISION & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES
 AS NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A
 RESULT OF THE ADDITIONAL INFORMATION REQUESTED
 ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF
 THIS REVIEW.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  