Date |
Text |
2015-06-19 14:03:06 | |
| BUILDING PLAN REVIEW |
| W. P. B. PERMIT: 15041121 |
| ADD: 1616 N FLORIDA MANGO |
| CONT: MARYJULI |
| TEL: ( 561)386-6032 |
| E-MAIL: [email protected] |
| |
| 2010 FLORIDA BUILDING CODE W |
| * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| |
| 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| OF THE FLORIDA BUILDING CODE, BUILDING. |
| |
| 1ST REVIEW |
| DATE: |
| ACTION: DENIED |
| |
| 1) SHEET A1 PLEASE SHOW COMPLIANCE WITH 2010 FBC-B |
| 416.7 SPRAY ROOMS SHALL BE SEPARATED BY 1 HOUR |
| SEPARATION FIRE BARRIERS. |
| |
| 2) SHEET A1 PLEASE SHOW COMPLIANCE WITH 2010 FBC-B |
| 416.7 SPRAY ROOMS. FLOORS SHALL BE WATER-PROOFED AND |
| DRAINED IN AN APPROVED MANNER. |
| |
| 3) SHOW COMPLIANCE WITH FBC-B 416.3 SPRAYING SURFACES. |
| SPRAYING SPACES SHALL BE VENTILATED WITH AN EXHAUST |
| SYSTEM TO PREVENT THE ACCUMULATION OF FLAMMABLE MIST OR |
| VAPORS IN ACCORDANCE WITH THE FBC-MECHANICAL CODE. |
| |
| 4) SHOW COMPLIANCE WITH 416.4 SPRAY BOOTHS SHALL BE |
| DESIGNED, CONSTRUCTED AND OPERATED IN ACCORDANCE THE |
| FLORIDA FIRE PREVENTION CODE. NFPA 33. |
| |
| 5) THE PLANS NEED TO SHOW COMPLIANCE WITH: FBC-B 416.5. |
| A AUTOMATIC FIRE EXTINGUISHING SYSTEM. |
| |
| 6) THE PLANS WILL NEED TO SHOW COMPLIANCE WITH HOW THE |
| ROOFTOP VENTS WILL BE ATTACHED/ ANCHORED TO RESIST THE |
| MOMENT OF OVERTURNING IN A 170 VULT MPH/ 3 SECOND GUST |
| WIND. THE ROOFTOP EXHAUST IS CONSIDERED COMPONENTS AND |
| CLADDING. |
| 2010 FBC-B 1609.1.1 DETERMINATION OF WIND DESIGN- |
| CHAPTER 6 OF ASCE 7-10. |
| 1609.3 BASIC WIND SPEED FIGURE 1609.A-C |
| 1609.3 WIND SPEED CONVERSION |
| |
| 6.1) THE BASIC WIND SPEED, VU, SHALL BE DETERMINED IN |
| ACCORDANCE WITH 1609.3.1 & ASCE 7-10 |
| |
| 6.2) AN IMPORTANCE FACTOR, FIGURE 1609 A-C, ASCE 7-10. |
| |
| 6.3) AN EXPOSURE CATEGORY SHALL BE DETERMINED IN |
| ACCORDANCE WITH 1609.4 & ASCE 7-10 |
| |
| 6.4) A HEIGHT AND EXPOSURE ADJUSTMENT COEFFICIENT, * |
| SHALL BE DETERMINED FROM TABLE 1609.7.2. ASCE 7-10. |
| |
| 6.5) COMPONENTS & CLADDING PRESSURES POSITIVE & |
| NEGATIVE TABLE 1609.2(2) . |
| |
| 7) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION |
| & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS |
| NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| COOPERATION. |
| |
| A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A |
| RESULT OF THE ADDITIONAL INFORMATION REQUESTED |
| ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF |
| THIS REVIEW. |
| |
| JAMES A. WITMER CBO |
| SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| TEL: 561-805-6715 |
| FAX: 561-805-6676 |
| E-MAIL: [email protected] |
| |
| |