2015-05-05 16:55:11BUILDING PROVISO;
 SUITE 2505-B GREY BOX
 1) TENANT BUILDOUT WILL EXCEED COMMON PATH OF TRAVEL
 WITH FIXTURES IN PLACE REQUIRING (2) EXITS. THE 2ND
 MEANS OF EGRESS THROUGH THE STORAGE/ STOCK ROOM WILL
 NEED TO COMPLY WITH:
 2010 FBC-B 1014.2.4 EXCEPTION # 2. MEANS OF EGRESS ARE
 NOT PROHIBITED THROUGH STOCKROOMS IN GROUP M
 OCCUPANCIES WHEN ALL OF THE FOLLOWING ARE MET:
  
 2.1. THE STOCK IS OF THE SAME HAZARD CLASSIFICATION AS
 THAT FOUND IN THE MAIN RETAIL AREA;
  
 2.2. NOT MORE THAN 50 PERCENT OF THE EXIT ACCESS IS
 THROUGH THE STOCKROOM;
  
 2.3. THE STOCKROOM IS NOT SUBJECT TO LOCKING FROM THE
 EGRESS SIDE; AND
  
 2.4. THERE IS A DEMARCATED, MINIMUM 44-INCH-WIDE (1118
 MM) AISLE DEFINED BY FULL- OR PARTIAL-HEIGHT FIXED
 WALLS OR SIMILAR CONSTRUCTION THAT WILL MAINTAIN THE
 REQUIRED WIDTH AND LEAD DIRECTLY FROM THE RETAIL AREA
 TO THE EXIT WITHOUT OBSTRUCTIONS.
  