| PROJECT: PHOTOVOLTAIC SYSTEM 3121 WASHINGTON RD |
| PERMIT#: 15040374 |
| CODE: 2008 EDITION OF THE NEC, 2010 EDITION OF THE FBC |
| ,2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, |
| ADMINISTRATION, 2012 FBC SUPPLEMENTS. |
| 1ST ELECTRICAL PLAN REVIEW |
| ACTION: DENIED |
| |
| 1) PROVIDE SITE PLAN INCLUDING THE FOLLOWING: WPB |
| AMENDMENTS TO THE FBC 107.3.2 |
| THE LOCATION HOUSE ON THE PROPERTY. |
| THE LOCATION OF THE PHOTOVOLTAIC DC DISCONNECT / |
| INVERTER ON THE HOUSE. |
| THE LOCATION OF THE ELECTRICAL UTILITY METER ON THE |
| HOUSE. |
| THE LOCATION OF THE ELECTRICAL SERVICE PANEL ON OR IN |
| THE HOUSE. |
| |
| 2) PROVIDE ALL SIGNAGE REQUIRED BY THE NEC 690 |
| |
| 3) INDICATE THE LOCATION OF EACH OF THE REQUIRED SIGNS |
| IN RELATION TO THE NEW PHOTOVOLTAIC EQUIPMENT AND THE |
| EXISTING ELECTRICAL EQUIPMENT. NEC 690 |
| |
| 4) PROVIDE MANUFACTURER PRODUCT APPROVALS ON EQUIPMENT |
| INDICATING COMPLIANCE WITH LISTING REQUIRMENTS. NEC |
| 690,4(D) |
| |
| 5) INDICATE A GROUNDING ELECTRODE DETAIL AT THE |
| ELECTRICAL SERVICE AND INDICATE HOW THE SOLAR ARRAY |
| GROUNDING ELECTRODE CONNECTS TO THE ELECTRICAL SYSTEM |
| GROUNDING ELECTRODE SYSTEM. |
| |
| WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| RE-SUBMITTAL FORM. SEE LINK: |
| HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/ |
| 2013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF |
| |
| ADDITIONALLY, IT IS REQUIRED TO INSERT THE CORRECTED |
| PAGES INTO THE DENIED SUBMITTAL PACKAGE. VOID THE |
| PREVIOUSLY REVIEWED SHEETS AND LEAVE FOR COMPARATIVE |
| REVIEW. |
| |