Plan Review Notes For Permit 15040340 |
Permit Number |
15040340 |
|
Review Stop |
E |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2015-05-15 10:26:22 | APPROVED WITH EXCEPTION. THE PLANS HAVE BEEN APPROVED | | PROVISIONALLY. FAILURE TO CORRECT THE LISTED | | DEFICIENCIES PRIOR TO INSPECTION WILL RESULT IN FAILED | | INSPECTION(S) AND THE ASSESSMENT OF RE-INSPECTION | | FEE(S). | | | | 1) VERIFY OR INSTALL SMOKE DETECTORS AS REQUIRED. WHEN | | ALTERATIONS, REPAIRS, OR ADDITIONS REQUIRING A PERMIT | | OCCUR, OR WHEN ONE OR MORE SLEEPING ROOMS ARE ADDED OR | | CREATED IN EXISTING DWELLINGS, THE INDIVIDUAL DWELLING | | UNIT SHALL BE EQUIPPED WITH SMOKE ALARMS LOCATED AS | | REQUIRED FOR NEW DWELLINGS. FBC-RESIDENTIAL 314 AND | | 315. | | | | 2) RECESSED LUMINAIRES INSTALLED IN THE BUILDING | | THERMAL ENVELOPE SHALL BE IC AND AIR TIGHT RATED AND | | SEALED TO LIMIT AIR LEAKAGE BETWEEN CONDITIONED AND | | UNCONDITIONED SPACES. FBC-E 502.3.8 RECESSED LIGHTING. | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | 561-805-6717 OR [email protected] |
|