2015-07-13 11:53:59 | BUILDING PLAN REVIEW |
| W. P. B. PERMIT: 15040016 |
| ADD: 701 N. ROSEMARY AVE. |
| CONT: ADVANCED CONSTRUCTION |
| TEL: (561)262-6037 |
| E-MAIL: |
| |
| 2010 FLORIDA BUILDING CODE W |
| * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| |
| 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| OF THE FLORIDA BUILDING CODE, BUILDING. |
| |
| 4TH REVIEW |
| DATE: MON. JULY 13/2015 |
| ACTION: DENIED |
| |
| NOTICE !!!!!! THE 2ND SET OF PLANS WERE SUBMITTED, |
| MISSING SHEET AD101, DATED 3/25/15. |
| |
| 1) COMPLIED. |
| |
| |
| 2) BUILDING PROVISO: PLANS RED LINED FOR ACCESSIBILITY. |
| SHEET AD103 TO MEET W. P. B. CITY STANDARD OF DOUBLE |
| STRIPING SEE W.P. B. MUNI CODE SECTION 94-485. |
| |
| 3) COMPLIED. ACCESSIBLE ACCESS AISLE AND WLKWAY TO |
| ACCESSIBLE ENTRY. |
| |
| 4) COMPLIED> PLANS DO NOT INDICATE COMPLIANCE WITH 2010 |
| FL ACCESS. CODE 904.4 SALES AND SERVICE COUNTERS. |
| SALES COUNTERS AND SERVICE COUNTERS SHALL COMPLY WITH |
| 904.4.1 OR 904.4.2. THE ACCESSIBLE PORTION OF THE |
| COUNTER TOP SHALL EXTEND THE SAME DEPTH AS THE SALES OR |
| SERVICE COUNTER TOP. |
| |
| 5) COMPLIED.WIND DESIGN CRITERIA |
| |
| 6A) 3RD REQUEST. SHEET AD201 HAS A CHANGE IN WINDOW |
| STYLE, THE LAST SUBMITTAL THE FRONT ELEVAION INDICATED |
| THE USE OF PGT SERIES PW 3020 PICTURE WINDOWS, |
| SUBMITTED NOA 12-0516.05. THIS SUBMITTAL SHEET AD201 |
| THE FRONT ELEVATION NOW SHOWS STOREFRONT WINDOW SYSTEM. |
| THE SUBMITTED NOA US ALUMINUM NOA # 14-0331.02 HAS NOT |
| BEEN REVIEWED BY THE DESIGNER OF RECORD. |
| |
| 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS |
| WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE |
| REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF |
| RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. |
| FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR |
| SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, |
| SHOP DRAWINGS ETC.. |
| |
| 6B)COMPLIED. |
| |
| 7) NOT APPLICABLE NO NEW ROOF SYSTEM. |
| |
| 8) PROVISO: A REVISION MAYBE NECESSARY TO SHOW |
| ADDITIONAL DETAILS. SHEET AS201 SHOW DETAIL 2 OOF |
| FRAMING FOR THE SIDEWALL & NEW ROOF. THIS DETAIL FAILS |
| TO PROVIDE THE CONNECTION TO THE EXISTING ROOF FRAMING, |
| DOES THE EXISTING LAST FRAMING MEMBER GET DOUBLED? DOES |
| THIS FRAMING MEMBER REQUIRE ADDITIONAL STAPPING FOR THE |
| ADDITIONAL UPLIFT OF A LARGER TRIBUTARY AREA AND BEING |
| PART OF THE MWFRS? |
| |
| 9) IMPACT FEES. BEFORE A PERMIT TO CONSTRUCT, MAY BE |
| ISSUED, IMPACT FEES MUST BE PAID TO PALM BEACH COUNTY. |
| THE ACTUAL PERMIT SET OF PLANS MUST BE STAMPED BY THAT |
| OFFICE, AND A COPY OF THE PAID RECEIPT ATTACHED TO THE |
| PERMIT APPLICATION. PLEASE CALL (561)233-5025 FOR MORE |
| INFORMATION. |
| |