2015-08-25 07:58:50 | 1ST REVIEW: FBC 2010 |
| |
| THE VALUATION FOR THE PROPOSED WORK IS LOW AND THE |
| SCOPE OF WORK IS UNCLEAR. PROVIDE JUSTIFICATION FOR THE |
| CLAIMED VALUE OR REVISE VALUE AND PROVIDE A FULL SCOPE |
| OF WORK. |
| FBC 109.3 BUILDING PERMIT VALUATION. FOR PERMITTING |
| PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS SHALL BE |
| TOTAL REPLACEMENT VALUE TO INCLUDE STRUCTURAL, |
| ELECTRIC, PLUMBING, MECHANICAL, INTERIOR FINISH, |
| RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN FEES, |
| MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING ONLY |
| LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE LATEST |
| PUBLISHED DATA OF NATIONAL CONSTRUCTION COST ANALYSIS |
| SERVICES (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY |
| INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT |
| VALUATION SHALL BE SET BY THE BUILDING OFFICIAL. |
| |
| FBC 107 - PROVIDE A SURVEY WITH FLOOD DESIGNATION. |
| |
| FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE |
| PRODUCTS WHICH ARE REGULATED BYFAC RULE 9N-3 REVIEWED |
| AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. |
| SPECIFICALLY, PROVIDE WINDOW, WINDOW MULLION, AND DOOR |
| SUBMITTALS. PROVIDE DESIGN PRESSURES FOR THE APPLICABLE |
| OPENINGS. |
| |
| THE FOLLOWING APPLIES TO THE GARAGE CONVERSION TO |
| LIVING SPACE: |
| |
| PER TABLE 101.4.1 NONEXEMPT EXISTING BUILDINGS, NOT |
| PREVIOUSLY CONDITIONED PERMITTED BEFORE MARCH 1979 AND |
| OCCUPANCY TYPE CHANGE MINIMUM EFFICIENCY LEVELS SHALL |
| BE MET FOR COMPONENTS BEING CHANGED ENVELOPE: SECTION |
| 402, WQUIPMENT: SECTION 403, LIGHTING: SECTION 404. |
| FBC 107.3.5.1.6 ENERGY CALCULATIONS - PROVIDE AN ENERGY |
| SUBMITTAL COMPLIANT WITH FBC-E 103 |
| |
| FBCR TABLE R302.1 EXTERIOR WALLS; MINIMUM |
| FIRE-RESISTANCE RATING WITHIN 3 FEET OF PROPERTY LINE |
| IS: 1 HOUR-TESTED IN ACCORDANCE WITH ASTM E 119 OR UL |
| 263 WITH EXPOSURE FROM BOTH SIDES. PROVIDE DETAILS TO |
| DEMONSTRATE COMPLIANCE WITH THE FORGOING. FOR THE REAR |
| AND WEST WALLS. |
| |
| FBC 107. PROVIDE FRAMING DETAILS FOR THE INSTALLATION |
| OF THE NEW WINDOW AND NEW DOOR. |
| |
| A TYPICAL BEARING WALL DETAIL IS PROVIDED. PLEASE |
| CLARIFY WHY THE DETAIL IS PROVIDED AND WHAT WORK |
| DEPICTED THERRE IS PROPOSED AS NEW. |
| |
| A COMPLETE REVIEW CANNOT BE COMPLETED DUE TO THE LACK |
| OF CLARITY OF THE SUBMITTAL. |
| |
| 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. |
| CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN |
| UPON SUITABLE MATERIAL. ELECTRONIC MEDIA DOCUMENTS |
| SHALL BE SUBMITTED WHEN APPROVED BY THE BUILDING |
| OFFICIAL. CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT |
| CLARITY TO INDICATE THE LOCATION, NATURE AND EXTENT OF |
| THE WORK PROPOSED AND SHOW IN DETAIL THAT IT WILL |
| CONFORM TO THE PROVISIONS OF THIS CODE AND RELEVANT |
| LAWS, ORDINANCES, RULES AND REGULATIONS, AS DETERMINED |
| BY THE BUILDING OFFICIAL. SUCH DRAWINGS AND |
| SPECIFICATIONS SHALL CONTAIN INFORMATION, IN THE FORM |
| OF NOTES OR OTHERWISE, AS TO THE QUALITY OF MATERIALS, |
| WHERE QUALITY IS ESSENTIAL TO CONFORMITY WITH THE |
| TECHNICAL CODES. SUCH INFORMATION SHALL BE SPECIFIC, |
| AND THE TECHNICAL CODES SHALL NOT BE CITED AS A WHOLE |
| OR IN PART, NOR SHALL THE TERM "LEGAL" OR ITS |
| EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC |
| INFORMATION. |
| |
| |