2015-09-03 15:24:43BUILDING PLAN REVIEW
 W. P. B. PERMIT: 15030795
 ADD: 5390 GEORGIA AVE.
 CONT: TIM GIVENS BUILDING
 TEL: (561)533-5825
 E-MAIL: [email protected]
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 2ND REVIEW
 DATE: THURS. SEPT. 03/2015
 ACTION: DENIED
  
 1) COMPLIED.
  
 2)COMPLIED. THE CALCULATED VALUE OF THE PROPOSED
 PROJECT IS $214,564.00.
 LANDSCAPE 15,000.00
 PAVING 8,000.00
 LOW VOLTAGE 2,500.00
 _____________
 NET CALC. VALUE THIS PERMIT $189,064.00
  
 3) COMPLIED. THE SUBMITTED SOILS REPORTS .
  
 4A)(1) SEMI- COMPLIED. THE PLANS DO NOT PROVIDE
 OCCUPANCY SEPARATION WALLS. PLEASE IDENTIFY THE
 OCCUPANCY SEPARATION WALLS BETWEEN THE F1 & S1
 OCCUPANCIES AND HOUR RATING OF WALL AND OPENING
 PROTECTIVE.
 2010 FBC-B TABLE 508.4
 2010 FBC-B TABLE 715.4.
 UNKNOWN DOOR, NOT IDENTIFIED BETWEEN THE F1 & S1
 OCCUPANCIES. 107.2.1.3 ADDITIONAL INFORMATION IS
 REQUIRED.
  
 4A)(2) DOOR # 4 IS SHOWN TO BE IN A 2 HOUR FIRE RATED
 WALL, THE DOOR SCHEDULE INDICATES THIS DOOR IS TO HAVE
 GLAZING IN THE DOOR, PLEASE PROVIDE THE AMOUNT OF SQ.
 INCHES IN THIS DOOR. 2010 FBC-B TABLE 715.5.4.
  
 4B) SPECIFIC OCCUPANCY REQUIREMENTS: NOTE IF THE
 CARPENTRY STUDIO AND OR CARPENTER WORK SHOP SHOW
 COMPLIANCE WITH:
  
 4B) (1) COMPLIED. NOTE LESS THAN 2500 SQ. FT. SCALES ON
 PLAN 2105 SQ. FT. W FBC-M 903.2.4.1 WOODWORKING
 OPERATIONS. AN AUTOMATIC SPRINKLER SYSTEM SHALL BE
 PROVIDED THROUGHOUT ALL GROUP F-1 OCCUPANCY FIRE AREAS
 THAT CONTAIN WOODWORKING OPERATIONS IN EXCESS OF 2,500
 SQUARE FEET (232 M2) IN AREA WHICH GENERATE FINELY
 DIVIDED COMBUSTIBLE WASTE OR USE FINELY DIVIDED
 COMBUSTIBLE MATERIALS.
  
 4B)(2) EXISTING OCCUPANCY. FBC-M 503.2 FANS. PARTS OF
 FANS IN CONTACT WITH EXPLOSIVE OR FLAMMABLE VAPORS,
 FUMES OR DUSTS SHALL BE OF NONFERROUS OR NONSPARKING
 MATERIALS, OR THEIR CASING SHALL BE LINED OR
 CONSTRUCTED OF SUCH MATERIAL. WHEN THE SIZE AND
 HARDNESS OF MATERIALS PASSING THROUGH A FAN ARE CAPABLE
 OF PRODUCING A SPARK, BOTH THE FAN AND THE CASING SHALL
 BE OF NONSPARKING MATERIALS. WHEN FANS ARE REQUIRED TO
 BE SPARK RESISTANT, THEIR BEARINGS SHALL NOT BE WITHIN
 THE AIRSTREAM, AND ALL PARTS OF THE FAN SHALL BE
 GROUNDED. FANS IN SYSTEMS-HANDLING MATERIALS THAT ARE
 CAPABLE OF CLOGGING THE BLADES, AND FANS IN BUFFING OR
 WOODWORKING EXHAUST SYSTEMS, SHALL BE OF THE
 RADIAL-BLADE OR TUBE-AXIAL TYPE.
  
 4B)(3) EXISTING OCCUPANCY. FBC-M [F] 510.2.1 LUMBER
 YARDS AND WOODWORKING FACILITIES.
 EQUIPMENT OR MACHINERY LOCATED INSIDE BUILDINGS AT
 LUMBER YARDS AND WOODWORKING FACILITIES WHICH GENERATES
 OR EMITS COMBUSTIBLE DUST SHALL BE PROVIDED WITH AN
 APPROVED DUST-COLLECTION AND EXHAUST SYSTEM INSTALLED
 IN CONFORMANCE WITH THIS SECTION AND THE FLORIDA FIRE
 PREVENTION CODE. EQUIPMENT AND SYSTEMS THAT ARE USED TO
 COLLECT, PROCESS OR CONVEY COMBUSTIBLE DUSTS SHALL BE
 PROVIDED WITH AN APPROVED EXPLOSION-CONTROL SYSTEM.
  
 4B)(4) EXISTING OCCUPANCY. FBC-M 511.4 WOOD PROCESSING
 AND WOODWORKING FACILITIES.
 WOOD PROCESSING FACILITIES THAT PRODUCE OR UTILIZE
 FINELY DIVIDED WOOD PARTICLES OR WOOD FIBERS SHALL
 CONFORM WITH NFPA 664.
 EXCEPTION: FACILITIES WITH AN AREA OF 2,000 SQUARE FEET
 (185.8 M2) OR LESS AND HAVE A DUST COLLECTION FLOW RATE
 OF 1500 CUBIC FEET PER MINUTE (0.708 M3/SEC) OR LESS.
  
 5) 2ND REQUEST . SHEET A100 THE RESTROOM DOES NOT
 COMPLY WITH THE 2010 FL ACCESSIBILITY CODE 604.3.2.
  
 6) COMPLIED. SHEET A100 THE CONFERENCE ROOM SHOWS A WET
 BAR PLEASE SHOW COMPLIANCE WITH 2010 FL ACC. CODE
 606.1-5.
  
 7) COMPLIED. SHEET A100 THE RECEPTION DESK DOES NOT
 INDICATE COMPLIANCE WITH 2010 FBC- ACCESS. 04.4 SALES
 AND SERVICE COUNTERS. SALES COUNTERS AND SERVICE
 COUNTERS SHALL COMPLY WITH 904.4.1 OR 904.4.2.
  
 8 )COMPLIED. SHEET A400 THE DOORS IDENTIFIED AS 2 & 3
 IN THE DOOR SCHEDULE AS A 2 FT. 8 INCH DOORS. 2010 FL
 ACC. CODE THE DOORS WILL NEED TO COMPLY WITH 404.2.3
 CLEAR WIDTH. DOOR OPENINGS SHALL PROVIDE A CLEAR WIDTH
 OF 32 INCHES (815 MM) MINIMUM. CLEAR OPENINGS OF
 DOORWAYS WITH SWINGING DOORS SHALL BE MEASURED BETWEEN
 THE FACE OF THE DOOR AND THE STOP, WITH THE DOOR OPEN
 90 DEGREES.
  
 9) COMPLIED. THE DOOR THAT LEADS TO THE RESTROOM DOES
 NOT COMPLY WITH 2010 FL ACCESS. CODE 404.2.4
 MANEUVERING CLEARANCES REQUIRING 18 INCHES ON THE LATCH
 SIDE OF THE DOOR. THERE IS A DOOR IDENTIFICATION TAG #
 6 BUT THERE ARE 2 DOORS IN THIS LOCATION WHICH IS IT
 FOR, OR FOR BOTH?
  
 8A) 2ND REQUEST, NOTE THE WIND DESIGN FOUND ON S-4.0
 INDICATES THE EXPOSURE AS A ?D? SHOULD BE A ?C? BUT NOT
 A ?B?.
 SHEET S-3.0 THE ROOF WIND DESIGN IS OFF, THE POSITIVE
 PRESSURES ARE HIGHER THAN THE NEGATIVE PRESSURES, THE
 OTHER ISSUE, ZONES 2 & 3 HAVE THE SAME PRESSURE, THE
 ROOF WIND DESIGN CHART DOES NOT INDICATE IF THESE
 VALUES ARE IN VULT OR VASD OR WHAT SQ. FT OF TRIBUTARY
 AREA THIS CHART IS FOR. 2010 FBC-B 1609.1.1
 DETERMINATION OF WIND DESIGN- CHAPTER 6 OF ASCE 7-10.
  
 8B) COMPLIED. SHEET S4.0 THE WINDOW AND DOOR PRESSURES
 ARE PROVIDED. THE NORTH ELEVATION THE CORNER ZONE # 5
 THE WINDOW PRESSURES ARE LOW. THE SOUTH ELEVATION OF
 THE NORTH WING THE PRESSURES ARE LOW IN ZONES 5 THE
 UPPER AND LOWER WINDOWS, IN ZONE 4 THE UPPER AND LOWER
 WINDOW PRESSURES ARE ALSO LOW. 2010 FBC-B 1609.1.1
 DETERMINATION OF WIND DESIGN- CHAPTER 6 OF ASCE 7-10.
  
 8C) 2ND REQUEST, HAND WRITTEN ON SHEET A -100.
 PRESSURES FOR THE OFFICE DOOR ARE NOT PROVIDED. 2010
 FBC-B 1609.1.1 DETERMINATION OF WIND DESIGN- CHAPTER 6
 OF ASCE 7-10.
  
 8D) THE SOUTH WING NORTH ELEVATION THE PRESSURES ARE
 LOW FOR BOTH WINDOW ZONES 4 & 5. 2010 FBC-B 1609.1.1
 DETERMINATION OF WIND DESIGN- CHAPTER 6 OF ASCE 7-10.
 THE GARAGE DOOR PRESSURES ARE ALSO LOW..
  
 8E) 2ND REQUEST, HAND WRITTEN IN ON SHEET A-100. DOOR 8
 ON THE SOUTH WING PRESSURES ARE NOT PROVIDED.
  
 9-10) COMPLIED.
  
 11) SEMI-COMPLIED. NO ROOFING SUBMITTALS HAVE BEEN
 PROVIDED FOR WOOD DECKS.
 APPROVED. NOA 10-0608.05 SEALOFLEX WATERPROOFING SYSTEM
 FOR CONCRETE DECKS .
  
 12) COMPLIED. 2010 FBC 107.3.4.1 PRODUCT APPROVALS.
 THOSE PRODUCTS WHICH ARE REGULATED BY THE DCA RULE
 9N-03 SHALL BE REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR
 JURISDICTIONAL APPROVAL.
  
 13) NOTICE ONLY! THIS PROJECT HAS REQUESTED PRIVATE
 PROVIDER TEW & TAYLOR FOR ONSITE INSPECTIONS. FORMS
 HAVE BEEN SUBMITTED AND FILED OUT.
  
 13A)NOTICE ONLY! PLEASE CALL THE CITY OF WEST PALM
 BEACH?S AUTOMATED TELEPHONE INSPECTIONS LINE (561)
 805-6700) FOR IN-PROGRESS INSPECTIONS FOR AUDITING OF
 JOBSITE INSPECTIONS.
  
 14) COMPLIED. BEFORE A PERMIT TO CONSTRUCT, MAY BE
 ISSUED, IMPACT FEES MUST BE PAID TO PALM BEACH COUNTY.
 THE ACTUAL PERMIT SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT ATTACHED TO THE
 PERMIT APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 15) WHEN RESUBMITTING PLANS PLEASE INDICATE THE
 REVISION & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES
 AS NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 DEVELOPMENT SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
 MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF
 FLORIDA SAVING LIVES AND PROPERTY SINCE 1953
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved