2015-03-20 06:45:47 | ****CORRECTIONS**** |
| SAMANTHA HILL, BUILDING PLANS EXAMINER |
| 561-805-6724 [email protected] |
| FBC FLORIDA BUILDING CODE 2010 |
| FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL |
| |
| |
| 1. COMPLETE THE SAMPLE INSTALLATION SCHEDULE OR PROVIDE |
| ALL INFORMATION TO SHOW CODE COMPLIANCE IN ANOTHER |
| FORMAT, FBC*106, FBC R301, FBC1609. TWO SETS REQUIRED. |
| THIS FORM IS AVAILABLE IN THE LOBBY OR ON THE INTERNET |
| AT |
| |
| HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/ |
| 2013/09/SCHEDULE_FOR_INSTALLATION.PDF |
| |
| INSTALLATION SCHEDULE TIPS - READ THE FOLLOWING ONLY IF |
| YOU ARE UNFAMILIAR WITH THIS FORM AND NEED ASSISTANCE: |
| |
| THE FOLLOWING IS A GUIDE TO ASSIST WITH COMPLETION OF |
| THE COLUMNS IN THE INSTALLATION SCHEDULE MOST OFTEN |
| FAILED IN PLAN REVIEW. IT IS RECOMMENDED THAT THE |
| CONTRACTOR CIRCLE THE PERTINENT INFORMATION IN THE |
| PRODUCT APPROVAL. IF PROPOSED INSTALLATION IS CLEAR, AN |
| EFFORT WILL BE MADE TO REDLINE THE INSTALLATION |
| SCHEDULE IF NECESSARY. |
| |
| SHUTTER CONNECTION MOUNTING TYPE: THIS IS NOT THE |
| FASTENER PROPOSED. THE INFORMATION IN THIS COLUMN |
| SHOULD CORRELATE WITH THE ANCHOR CHARTS. MOST PRODUCT |
| APPROVALS HAVE ANCHOR CHARTS WHICH SPECIFY THE ANCHOR |
| SPACING. FIRST, LOCATE THE ANCHOR CHARTS IN THE PRODUCT |
| APPROVAL. NOTE THE NAMING CONVENTION. THE MOST COMMON |
| NAMING CONVENTIONS ARE THE FOLLOWING: |
| |
| C1, C2, C3, C4, C5 |
| 1 (TOP), 1 (BOTTOM); 2 (TOP), 2 (BOTTOM), ETC. |
| |
| WITH THE NAMING CONVENTION IN MIND, LOCATE THE |
| INSTALLATION MOUNTING DETAILS IN THE PRODUCT APPROVAL. |
| DETERMINE WHICH INSTALLATION METHOD YOU PROPOSE. THE |
| SHUTTER CONNECTION MOUNTING TYPE WILL BE INDICATED |
| WITHIN THE DETAIL. |
| |
| SHUTTER SPAN: FOR ACCORDION SHUTTERS, THIS DIMENSION IS |
| THE BLADE LENGTH. FOR PANELS AND MOST OTHER TYPES OF |
| IMPACT PROTECTION, THIS IS THE DIMENSION FROM ANCHOR TO |
| ANCHOR. |
| |
| SHUTTER INSTALLED VERTICAL/HORIZONTAL: ACCORDIONS ARE |
| INSTALLED VERTICALLY; PANELS CAN BE INSTALLED EITHER |
| VERTICALLY OR HORIZONTALLY. THIS COLUMN CORRELATES WITH |
| THE CONFIGURATION OF THE ANCHORS (ANCHORS AT TOP AND |
| BOTTOM = VERTICAL, ANCHORS AT SIDES OF OPENING = |
| HORIZONTAL). |
| |
| SUBSTRATE: FOR MOST VERTICAL INSTALLATIONS, CBS |
| STRUCTURE, THE TOP IS USUALLY CONCRETE, BOTTOM IS |
| USUALLY BLOCK (MASONRY) UNLESS THE PRODUCT APPROVAL |
| INCLUDES A CHART FOR GROUT FILLED BLOCK. FOR HORIZONTAL |
| INSTALLATIONS, UNLESS THE STRUCTURE HAS CONCRETE WALLS |
| RATHER THAN CBS, THE SUBSTRATE IS MASONRY OR GROUT |
| FILLED BLOCK (IF THAT SUBSTRATE IS INCLUDED IN THE |
| PRODUCT APPROVAL). ONLY A FORMED AND POURED CONCRETE |
| SUBSTRATE IS CONSIDERED CONCRETE FOR THIS PURPOSE. |
| |
| ANCHOR SPACING: THIS IS DETERMINED BY LOCATING THE |
| PROPOSED DESIGN PRESSURE, SHUTTER CONNECTION MOUNTING |
| TYPE, SUBSTRATE AND ANCHOR TYPE IN THE PRODUCT APPROVAL |
| ANCHOR CHARTS. THE MOST COMMON ERROR IS THE USE OF THE |
| CONCRETE CHART. IN SOME PRODUCT APPROVALS, SOME |
| MOUNTING TYPES ARE LIMITED TO CONCRETE AND WOOD |
| SUBSTRATES ONLY. READ THE INFORMATION AT THE TOP OF THE |
| CHART CAREFULLY. |
| |
| WHY IS THIS REQUIRED? |
| |
| THIS FORM (OR ALL OF THE INFORMATION CONTAINED ON THE |
| FORM PROVIDED IN ANOTHER FORMAT) IS USED IN PLAN REVIEW |
| TO DETERMINE THAT THE PROPOSED INSTALLATION IS |
| CONSISTENT WITH THE REQUIREMENTS IN THE PRODUCT |
| APPROVAL. IN THE FIELD, IT ASSISTS THE INSPECTOR TO |
| PERFORM THE INSPECTION QUICKLY AND ACCURATELY. |
| |