2015-05-27 03:30:15 | 1)THE PERMIT APPLICATION AND PLANS ARE VAGUE AS TO THE |
| EXTENT OF PLUMBING WORK THAT WILL BE DONE IN THIS |
| SPACE.SUBMIT INFORMATION AND ON THE PLANS SHOWING THE |
| ENTIRE SCOPE OF PLUMBING WORK TO BE DONE.107.1.2. |
| SUBMIT TWO COPIES OF CLEAR AND LEGIBLE PLANS FOR |
| REVIEW. ONE SET OF PLANS IS SO LIGHT THEY ARE |
| ILLEGIBLE.PLANS SHALL BE DRAWN ON A MIN. OF 1/8 " SCALE |
| AND SHALL CLEARLY SHOW THE SCOPE OF WORK TO BE DONE. |
| WPB AMEND. TO 2010 FBC SEC. 107.2.1 |
| 2) IS ANY EQUIPMENT/ PEDICURE CHAIRS THAT USE WATER |
| BEING INSTALLED? IF SO, SUBMIT MANUFACTURER'S |
| SPECIFICATIONS & INSTALLATION INSTRUCTIONS FOR THE |
| EQUIPMENT.IDENTIFY THE CHAIRS ON THE PLAN IF |
| APPLICABLE. NOW THERE IS JUST IMAGES NOTED AS "SEAT |
| WITH STOOL". |
| 3) SUBMIT A WATER RISER FOR REVIEW. WPB AMEND. TO 2010 |
| FBC SEC.107.3.5.1.3. |
| 4) BOTH SETS OF PLANS SHALL BE SIGNED AND SEALED BY THE |
| DESIGN PROFESSIONAL OF RECORD PER THE FL. ADMIN. CODE |
| RULE 61G1-16.003. |
| 5)SHT. A-1 - HANDICAP DETAILS - THE GRAB BAR SHALL BE |
| MEASURED FROM THE FINISH FLOOR TO THE TOP OF THE |
| GRIPPING SURFACE, NOT TO THE CENTERLINE AS SHOW. FAC |
| SEC. 609.4. |
| 6) THE TOILET PAPER DISPENSER SHALL BE LOCATED 7-9 |
| INCHES IN FRONT OF THE WATER CLOSET MEASURED TO THE |
| CENTERLINE OF THE DISPENSER. SHOW THIS ON THE HANDICAP |
| DETAILS. |
| 7) THE FINISH SCHEDULE ON SHT A-1 NOTES THE TOILET ROOM |
| WALLS TO BE PAINTED AND A 2 INCH WOOD BASE |
| INSTALLED.THE BASE SHALL BE A MINIMUM OF 4 INCHES AND |
| COMPLY WITH FBC SEC.1210.1. THE WALLS & PARTITIONS |
| WITHIN 2 FEET OF WATER CLOSETS SHALL HAVE SMOOTH, HARD, |
| NONABSORBENT SURFACE, TO A HEIGHT OF 4 FEET ABOVE THE |
| FLOOR AND COMPLY WITH FBC SEC. 1210.2. |
| 8) INDICATE ON THE PLANS WHAT PLUMBING IS NEW AND WHAT |
| IS EXISTING TO REMAIN. WPB AMEND. TO FBC SEC. 107.2.1. |
| 9) SHT. E-1 SHOWS A 100 GALLON WATER HEATER. IS THIS |
| CORRECT? |
| 10) SHT. E-1 - SUBMIT A WATER RISER DIAGRAM FOR REVIEW. |
| WPB AMEND. TO FBC SEC. 107.3.5.1.3. THE PLAN VIEW |
| REQUIRES A MAGNIFYING GLASS TO REVIEW. PLANS SHALL BE |
| DRAWN ON A MIN. OF 1/8 " SCALE AND SHALL CLEARLY SHOW |
| THE SCOPE OF WORK TO BE DONE. WPB AMEND. TO 2010 FBC |
| SEC. 107.2.1 |
| |