2015-07-20 16:12:06PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC 2010
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) THE CLASSIFICATION OF WORK ON THE COVER SHEET
 SPECIFIES THIS AS A LEVEL 1 ALTERATION. THE PLANS
 INDICATE THAT THE SPACE HAS BEEN RECONFIGURED AND DOORS
 AND WINDOWS HAVE BEEN ADDED OR ELIMINATED. THIS PROJECT
 MEETS THE REQUIREMENTS FOR A LEVEL 2 ALTERATION. IF THE
 WORK AREA EXCEEDS 50 PERCENT OF THE AGGREGATE AREA OF
 THE BUILDING, THEN IT IS A LEVEL 3 ALTERATION. FBC
 EXISTING BUILDING 401.4
  
 2) SPECIFY THE WIND DESIGN CRITERIA AND THE REQUIRED
 DESIGN PRESSURES FOR THE (2) NEW EXTERIOR DOORS AND (1)
 WINDOW. FBC-R301.2.1
  
 3) FBC 107.3.4 - PROVIDE TWO COMPLETE SETS OF PRODUCT
 APPROVALS FOR THOSE PRODUCTS WHICH ARE REGULATED BY DCA
 RULE 9N-3 THAT HAVE BEEN REVIEWED AND APPROVED IN
 WRITING BY THE DESIGNER OF RECORD.
  
 4) THE ONE SET OF PRODUCT APPROVAL INSTALLATION
 DOCUMENTS THAT WERE SUBMITTED FOR THE JELD-WEN SLIDING
 PATIO DOOR DOES NOT HAVE A FLORIDA PRODUCT APPROVAL FL#
 ON THEM. SUBMIT THE COVER-SHEETS WITH THE FL#.
  
 5) THE DOOR SCHEDULE ON SHEET A-200 FOR DOOR #1
 SPECIFIES THE DOOR TYPE AS SLIDING AND SWING DOORS ARE
 INDICATED UNDER REMARKS FOR THIS DOOR. PRODUCT
 APPROVALS FOR BOTH EXTERIOR DOOR TYPES WERE SUBMITTED.
 PLEASE CLARIFY. FBC 107.2.1
  
 6) THE ENERGY FORM 402-2010 IS REQUIRED TO BE SIGNED
 AND DATED BY THE OWNER/AGENT. FBC ENERGY 103.2.3.2
  
 7) IN ORDER TO REDUCE PLAN REVIEW TIMES AND PROVIDE
 CLARIFICATION, PLEASE SUBMIT A RESPONSE LETTER
 INDICATING HOW EACH OF THE REVIEW COMMENTS HAS BEEN
 ADDRESSED.
  
  
  
  
  
  