Date |
Text |
2015-10-29 13:38:51 | BUILDING PLAN REVIEW |
| W. P. B. PERMIT: 15030515 |
| ADD: 3001 OKEECHOBEE BLVD. |
| CONT: HEDRICK BROTHERS |
| TEL: (561)689-8880 |
| E-MAIL: [email protected] |
| |
| 2010 FLORIDA BUILDING CODE W |
| * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| |
| 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| OF THE FLORIDA BUILDING CODE, BUILDING. |
| |
| 3RD REVIEW |
| DATE: THURS. OCT. 29/2015 |
| ACTION: DENIED |
| |
| NOTE: CHANGED FROM DIGITAL TO PAPER PLANS. IN SOME |
| CASES YOU WILL SEE 2ND REVIEW, IN A FEW CASES WHEN THE |
| PROJECT WAS A ELECTRONIC REVIEW SOME COMMENTS WERE |
| SATISFIED BUT WITH THIS PAPER SUBMITTAL THE COMMENTS |
| THAT WERE SATISFIED WOULD HAVE NEEDED THE BACK UP PAPER |
| DOCUMENTS, SINCE THE CONTRACTOR HAS ELECTED TO RESUBMIT |
| IN PAPER. |
| |
| 1) THIS PERMIT WILL REQUIRE A RESIDENT INSPECTOR ON |
| SITE FOR BUILDINGS WITH STRUCTURAL STEEL, WELDABLE |
| JOINTS AND OR BOLTABLE JOINTS, BAR JOIST AND STEEL ROOF |
| DECKING AND OR SHORING REQUIREMENTS. |
| 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING |
| CODE, CHAPTER 1, ADMINISTRATION, 110.3.9 OTHER |
| INSPECTIONS SERVICES. THE BUILDING OFFICIAL MAY MAKE, |
| OR CAUSE TO BE MADE BY OTHERS, THE INSPECTIONS REQUIRED |
| BY SECTION 109. HE/SHE MAY ACCEPT REPORTS OF INSPECTORS |
| OF RECOGNIZED INSPECTION SERVICES, PROVIDED THAT AFTER |
| INVESTIGATION HE/SHE IS SATISFIED AS TO THEIR |
| QUALIFICATIONS AND RELIABILITY. A CERTIFICATE CALLED |
| FOR BY ANY PROVISION OF THE TECHNICAL CODES SHALL NOT |
| BE BASED ON SUCH REPORTS UNLESS THE SAME ARE IN WRITING |
| AND CERTIFIED BY A RESPONSIBLE OFFICER OF SUCH SERVICE. |
| THE BUILDING OFFICIAL MAY REQUIRE THE OWNER TO EMPLOY |
| AN INSPECTION SERVICE IN THE FOLLOWING INSTANCES: |
| |
| 1. FOR BUILDINGS OR ADDITIONS OF TYPE I OR II |
| CONSTRUCTION |
| 2. FOR ALL MAJOR STRUCTURAL ALTERATIONS |
| 7. FOR BUILDINGS AND STRUCTURES OF UNUSUAL DESIGN OR |
| METHODS OF CONSTRUCTION |
| |
| RESIDENT INSPECTOR FORMS MUST BE SIGNED BY ALL PARTIES |
| NOTARIZED AND RETURNED TO THE BUILDING DEPARTMENT. |
| |
| RESIDENT INSPECTOR FORMS WERE SENT : |
| [email protected] 4:04PM 06/23/15 |
| 2ND SET OF RESIDENT INSPECTOR FORMS WERE E-MAILED TO: |
| [email protected] 10/29/2015 01:50 PM |
| |
| 1A)SEMI-COMPLIED. RESIDENT INSPECTOR RESUME' RECEIVED. |
| THE BUILDING OFFICIAL OR HIS DESIGNEE WILL REVIEW THE |
| RESUME'. AFTER THE RESUME' IS REVIEWED, AN INTERVIEW |
| WILL BE SCHEDULED. UNDER NO CIRCUMSTANCES WILL AN |
| INSPECTOR BE INTERVIEWED FOR WORK WITHOUT FIRST MEETING |
| THE ABOVE CRITERIA. |
| CONTACT KEN CONRAD |
| TEL: 561-805-6666 |
| E-MAIL: [email protected] |
| |
| 1B) COMPLIED. CONTRACTOR JOB SUMMARY OR HISTORY FOR |
| THIS TYPE OF CONSTRUCTION. |
| |
| 1C) NOTICE ONLY NO ACTION NEED TO BE TAKEN AT THIS |
| TIME. FOR DIGITAL PLANS, AFTER PERMIT ISSUANCE, THE |
| PERMIT LIBRARIAN WILL E-MAIL YOU, THE APPROVED AND |
| BATCH STAMPED PLANS SO YOU MAY PRINT YOUR PLANS, TWO |
| SETS OF PLANS WILL NEED TO BE PRINTED IN COLOR, (1) FOR |
| THE RESIDENT INSPECTOR, THE OTHER FOR THE MEP |
| INSPECTORS. |
| |
| 1D)NOTICE ONLY, NO ACTION NEED TO BE TAKEN AT THIS |
| TIME. PLEASE CALL THE CITY OF WEST PALM BEACH?S |
| AUTOMATED TELEPHONE INSPECTIONS LINE (561) 805-6700) |
| FOR IN-PROGRESS INSPECTIONS FOR AUDITING OF JOBSITE |
| INSPECTIONS. |
| |
| 2) 2ND REQUEST. FOUNDATIONS WILL NEED SOILS ENGINEERS' |
| REPORT. SHEET S-3 FOUNDATION NOTE 1-A. 2010 FBC-B |
| 1803.5.2 QUESTIONABLE SOIL. |
| WHERE THE CLASSIFICATION, STRENGTH OR COMPRESSIBILITY |
| OF THE SOIL IS IN DOUBT OR WHERE A LOAD-BEARING VALUE |
| SUPERIOR TO THAT SPECIFIED IN THIS CODE IS CLAIMED, THE |
| BUILDING OFFICIAL SHALL BE PERMITTED TO REQUIRE THAT A |
| GEOTECHNICAL INVESTIGATION BE CONDUCTED. |
| |
| 3) SHEET S-3: |
| |
| 3A) THIS PERMIT WAS SUBMITTED ON MARCH 12/ 2015 UNDER |
| THE 2010 FBC-B. SHEET S-3 REFERENCES THE 2014 FBC, THE |
| 5TH EDITION OF THE FLORIDA BUILDING CODE, PLEASE |
| CORRECT. THE 5TH EDITION WAS NOT ADOPTED UNTIL JUNE 30/ |
| 2015 STATEWIDE. |
| |
| 3B) PLEASE PROVIDE WIND PRESSURES FOR UNDER THE 2010 |
| FBC-B IN VASD 140 MPH 3 SECOND GUST. 2010 FBC-B |
| 1609.1.1 DETERMINATION OF WIND DESIGN- CHAPTER 6 OF |
| ASCE 7-10. |
| |
| 3C) SHEET S3 THE VASD PRESSURES FOR 140 MPH VASD WITH A |
| MEAN ROOF HEIGTH OF APPROX. 16.5 FT ARE CORRECT FOR THE |
| ROOF ZONES, THE NEGATIVE PRESSURES FOR WALL ZONES 4 & 5 |
| ARE LOW FOR 10 SQ. FT. |
| |
| 4) 2ND REVIEW. COMPONENTS & CLADDING 2010 FBC-B |
| 1609.1.2 PROTECTION OF OPENINGS, 1609.6.4.41 COMPONENTS |
| & CLADDING |
| FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. |
| 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION |
| SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: |
| (31)(A) EXTERIOR DOORS & MULLIONS. |
| (B) WINDOWS & MULLIONS |
| (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL |
| LOUVERS, ACM PANELS, EFIS SYSTEMS, |
| (D) ROOFING PRODUCTS AND ASSEMBLIES, ROOF CURBS, |
| EXHAUST FANS |
| (G)PRE-ENGINEERED A/C STANDS |
| |
| 5) 2ND REQUEST. 1407.4 STRUCTURAL DESIGN. MCM SYSTEMS |
| SHALL BE DESIGNED AND CONSTRUCTED TO RESIST WIND LOADS |
| AS REQUIRED BY CHAPTER 16 FOR COMPONENTS AND CLADDING. |
| 1407.5 APPROVAL. RESULTS OF APPROVED TESTS OR AN |
| ENGINEERING ANALYSIS SHALL BE SUBMITTED TO THE BUILDING |
| OFFICIAL TO VERIFY COMPLIANCE WITH THE REQUIREMENTS OF |
| CHAPTER 16 FOR WIND LOADS. |
| |
| 6) 2ND REQUEST. 2010 FBC 107.3.4.1 PRODUCT APPROVALS. |
| THOSE PRODUCTS WHICH ARE REGULATED BY THE DCA RULE |
| 9N-03 SHALL BE REVIEWED AND APPROVED IN WRITING BY THE |
| DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR |
| JURISDICTIONAL APPROVAL. |
| FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR |
| SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, |
| SHOP DRAWINGS ETC.. |
| |
| |
| 7) COMPLIED. |
| |
| 8) PROVISO: ART IN PUBLIC PLACES. THE CITY OF WEST PALM |
| BEACH ART IN PUBLIC PLACES ORDINANCE REQUIREMENT THAT |
| APPLIES TO ANY REMODEL OR NEW CONSTRUCTION PROJECT FOR |
| WHICH THE PERMIT APPLICATION WAS SUBMITTED AFTER |
| 7/1/14, AND THE TOTAL PROJECT CONSTRUCTION COSTS ARE |
| EQUAL TO OR GREATER THAN $500,000. PER CITY OF WEST |
| PALM BEACH ORDINANCE NO. 4504-14, AND CITY OF WEST PALM |
| BEACH CODE OF ORDINANCES, ARTICLE V, ART IN PUBLIC |
| PLACES, SECTION 78-123(A) AND SECTION 78-126(A), THE |
| ART ASSESSMENT IS 1% OF THE TOTAL PROJECT CONSTRUCTION |
| COST. |
| |
| PER CITY OF WEST PALM BEACH CODE OF ORDINANCES, ARTICLE |
| V, ART IN PUBLIC PLACES, SECTION 78-122, RENOVATION AND |
| NEW CONSTRUCTION PROJECTS ARE ASSESSED CUMULATIVELY, SO |
| THE ART ASSESSMENT WILL BE APPLICABLE TO ALL FUTURE |
| PROJECTS. |
| |
| 9) IMPACT FEES BEFORE A PERMIT TO CONSTRUCT, MAY BE |
| ISSUED, IMPACT FEES MUST BE PAID TO PALM BEACH COUNTY. |
| THE ACTUAL PERMIT SET OF PLANS MUST BE STAMPED BY THAT |
| OFFICE, AND A COPY OF THE PAID RECEIPT ATTACHED TO THE |
| PERMIT APPLICATION. PLEASE CALL (561)233-5025 FOR MORE |
| INFORMATION. |
| |
| 10) WHEN RESUBMITTING PLANS PLEASE INDICATE THE |
| REVISION & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES |
| AS NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| COOPERATION |
| |
| JAMES A. WITMER CBO |
| SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| TEL: 561-805-6715 |
| FAX: 561-805-6676 |
| E-MAIL: [email protected] |
| |
| |
| JAMES A. WITMER CBO |
| SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| TEL: 561-805-6715 |
| FAX: 561-805-6676 |
| E-MAIL: [email protected] |
| |
| |
| |
| |
| |