Plan Review Notes
Plan Review Notes For Permit 15030486
Permit Number 15030486
Review Stop G
Sequence Number 1
Notes
Date Text
2015-03-13 09:40:201) SUBMIT MANUFACT. SPECS / INSTALLATION INDTRUCTIONS
 FOR ALL GAS EQUIPMENT. ALL EQUIPMENT SHALL BE LISTED
 AND LABELED PER THE 2010 FL. FUEL GAS CODE SEC.
 G2404.3.
 2) SHOW THE PIPE SIZE OF THE LINE BETWEEN THE METER AND
 THE TEE FOR THE POOL HEATER.
 3) INDICATE THE TYPE OF MATERIAL AND THE SIZE OF THE
 LINES FEEDING THE TANKLESS WATER HEATERS & THE
 RANGE/OVEN.
 4) SHOW THE LOCATIOM OF THE MEDIUM PRESSURE REGULATORS
 ON THE PLANS.
 5) SHOW THE LENGTH OF PIPE FROM THE REGULSTOR TO THE
 OUET FOR THE POOL HEATER.919 FBCR SEC.G2413.4.
 6) SHOW THE LOCATIONS AND SUBMIT MANUFACTURER'S
 SPECIFICATION SHEETS FOR THE 2 PSI REGULATORS PER THE
 2010 FBCR SEC.G2421.1.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692