Plan Review Notes
Plan Review Notes For Permit 15030431
Permit Number 15030431
Review Stop B
Sequence Number 4
Notes
Date Text
2015-07-29 16:56:38PLAN REVIEW COMMENTS
 4TH REVIEW: FBC 2010
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING - ( NOTE: THE PERMIT APPLICATION IS
 MISSING FROM THE CONSTRUCTION DOCUMENTS. A NEW
 REPLACEMENT APPLICATION IS REQUIRED. )
  
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) REPEAT COMMENT. THE PLANS SPECIFY NEW IMPACT RATED
 DOORS AND WINDOWS. FBC 107.3.4 - PROVIDE TWO SETS OF
 PRODUCT APPROVALS FOR THOSE PRODUCTS WHICH ARE
 REGULATED BY DCA RULE 9N-3 THAT HAVE BEEN REVIEWED AND
 APPROVED IN WRITING BY THE DESIGNER OF RECORD. PROVIDE
 TWO COMPLETE PRODUCT APPROVALS WITH FL OR NOA NUMBERS
 INCLUDING INSTALLATION INSTRUCTIONS AND MAXIMUM DESIGN
 PRESSURES FOR EACH OF THE WINDOW AND EXTERIOR DOOR
 TYPES. ONLY ONE SET OF PRODUCT APPROVALS WAS SUBMITTED
 FOR THE SINGLE HUNG WINDOWS (NOA NO. 14-0722.07).
  
 2) REPEAT COMMENT. FBC - R 301.2.1.2 SUBMIT TWO COPIES
 OF AN INSTALLATION SCHEDULE AND KEY PLAN FOR THE STORM
 PANELS. SPECIFY THE OPENING SIZE, THE WIND PRESSURES,
 TYPE OF ANCHOR, ANCHOR SPACING, EDGE DISTANCE, PANEL
 LENGTH, PANEL SPAN, SEPARATION DISTANCE FROM PANEL TO
 GLASS AND THE APPLICABLE SECTION NUMBER FROM THE
 INSTALLATION DRAWINGS. I HAVE INCLUDED A LINK TO THE
 CONSTRUCTION SERVICES DEPARTMENT SITE THAT HAS MANY OF
 THE RELATED FORMS INCLUDING
 THE SCHEDULE FOR INSTALLATION OF OPENING PROTECTIVE
 DEVICES.
 HTTP://WPB.ORG/DEVELOPMENT/FORMS-AND-PUBLICATIONS/
  
 3) THE REVISED PLANS AND THE RESPONSE LETTER INDICATE
 THAT THE FRONT DOOR IS TO BE LARGE MISSILE IMPACT RATED
 TO ALLOW FOR EGRESS WHEN THE STORM PANELS ARE IN PLACE
 DURING THE THREAT OF A STORM PER FBC - R310.4. SUBMIT
 TWO SETS OF PRODUCT APPROVALS FOR THE 3' 0" X 6' 8"
 IMPACT RATED FRONT DOOR THAT HAVE BEEN REVIEWED AND
 APPROVED IN WRITING BY THE DESIGNER OF RECORD. PROVIDE
 TWO COMPLETE PRODUCT APPROVALS WITH FL OR NOA NUMBERS
 INCLUDING INSTALLATION INSTRUCTIONS AND MAXIMUM DESIGN
 PRESSURES. FBC 107.3.4
  
 4) ONE SET OF PRODUCT APPROVALS WERE PREVIOUSLY
 SUBMITTED FOR EACH OF THE FOLLOWING NON-IMPACT RATED
 DOORS FL#16106 AND A JELD-WEN CONTOURS PREMIUM STEEL
 WOOD EDGE HALF LITE OUTSWING DOOR WITH NO FL# INDICATED
 ON THE DOCUMENTS. TWO SETS OF PRODUCT APPROVALS WERE
 SUBMITTED FOR NON-IMPACT RATED DOORS (FL#15255.13) WITH
 THE LAST RESUBMITTAL. PLEASE CLARIFY WHICH OF THESE
 WILL BE INSTALLED. AN ADDITIONAL SET OF PRODUCT
 APPROVALS THAT HAVE BEEN REVIEWED BY THE DESIGNER OF
 RECORD WILL BE REQUIRED IF YOU WISH TO USE THE FIRST
 TWO MENTIONED AND A COVER SHEET WITH THE FL# IS
 REQUIRED FOR THE HALF LITE DOOR. FBC 107.2.1
  
 5) THE PERMIT APPLICATION IS MISSING FROM THE
 CONSTRUCTION DOCUMENTS. A NEW REPLACEMENT APPLICATION
 IS REQUIRED.
  
 6) IN ORDER TO REDUCE PLAN REVIEW TIMES AND PROVIDE
 CLARIFICATION, PLEASE SUBMIT A RESPONSE LETTER
 INDICATING HOW EACH OF THE REVIEW COMMENTS HAS BEEN
 ADDRESSED.
  
  
  
  
  
  
  
  
  
  