2015-03-19 09:30:16 | 5335 NORTH MILITARY TRAIL |
| PERMIT #15030396 |
| REVIEW COMMENTS - FIRE DEPARTMENT |
| |
| PROVIDE A SCALABLE INTERIOR FLOOR PLAN SHOWING ALL EXIT |
| DOORS, OCCUPANCY TYPES, OCCUPANT LOADS, EXIT SIGNS, |
| EMERGENCY LIGHTING, PORTABLE FIRE EXTINGUISHERS, ETC. |
| |
| PROVIDE A DRAWING DETAIL OF THE STAIRS, HANDRAILS AND |
| GUARDRAILS. GUARDS, AT LEAST 42-INCHES TALL, SHALL BE |
| PROVIDED AT THE OPEN SIDES OF MEANS OF EGRESS (STAIRS, |
| MEZZANINE, ETC.) THAT EXCEED 30-INCHES ABOVE THE FLOOR. |
| OPEN GUARDS SHALL PROHIBIT THE PASSAGE OF A 4-INCH |
| DIAMETER SPHERE UP TO A HEIGHT OF 34-INCHES. THE |
| TRIANGULAR OPENINGS FORMED BY THE RISER, TREAD AND |
| BOTTOM ELEMENT OF THE GUARDRAIL SHALL PROHIBIT THE |
| PASSAGE OF A 6-INCH DIAMETER SPHERE. HANDRAILS ARE |
| REQUIRED ON BOTH SIDES OF THE STAIR. HANDRAILS SHALL BE |
| LOCATED NOT LESS THAN 34 INCHES AND NOT MORE THAN 38 |
| INCHES ABOVE THE SURFACE OF THE TREAD, MEASURED |
| VERTICALLY TO THE TOP OF THE RAIL FROM THE LEADING EDGE |
| OF THE TREAD. HANDRAIL ENDS SHALL BE RETURNED TO THE |
| WALL OR FLOOR OR SHALL TERMINATE AT NEWEL POSTS. |
| HANDRAIL CROSS SECTION SHALL HAVE A DIAMETER OF NOT |
| LESS THAN 1.25 INCHES AND NOT MORE THAN 2 INCHES. |
| |
| PROVIDE PORTABLE FIRE EXTINGUISHERS. EXTINGUISHERS |
| SHALL HAVE A MINIMUM RATING OF 2A:10BC AND SHALL BE |
| TAGGED BY A LICENSED FIRE EXTINGUISHER COMPANY. TRAVEL |
| DISTANCE TO EXTINGUISHERS SHALL NOT EXCEED 75 FEET. |
| |
| |
| WESLEY JOLIN |
| ASSISTANT FIRE MARSHAL |
| WEST PALM BEACH FIRE RESCUE |
| [email protected] |
| (561) 805-6730 |
| |