Date |
Text |
2015-08-10 11:58:50 | ****CORRECTIONS**** |
| |
| SAMANTHA HILL |
| BUILDING PLANS EXAMINER |
| [email protected] |
| 561-805-6724 |
| |
| COMMENTS FROM PREVIOUS LIST, NOT ADDRESSED: |
| |
| 1. PROVIDE PLANS FOR THE PROPOSED SHED, FBC 2010 |
| RESIDENTIAL 301. |
| |
| 2. FYI - OWNER BUILDER PERMITS NOT ALLOWED FOR RENTAL |
| PROPERTIES. A HOLD HAS BEEN PLACED ON THE FENCE PERMIT |
| WHICH WAS ISSUED IN ERROR. SUBMIT A CHANGE OF |
| CONTRACTOR AND APPLICATION FROM A CONTRACTOR LICENSED |
| TO PERFORM THIS WORK. IF THIS IS NOT DONE WITHIN SEVEN |
| WORKING DAYS, THE FENCE PERMIT WILL BE REVOKED (MADE |
| VOID). |
| |
| 3. SEE FLORIDA STATUTE 489, EXEMPTIONS: |
| |
| (20) THE SALE, DELIVERY, ASSEMBLY, OR TIE-DOWN OF |
| PREFABRICATED PORTABLE SHEDS THAT ARE NOT MORE THAN 250 |
| SQUARE FEET IN INTERIOR SIZE AND ARE NOT INTENDED FOR |
| USE AS A RESIDENCE OR AS LIVING QUARTERS. THIS |
| EXEMPTION MAY NOT BE CONSTRUED TO INTERFERE WITH THE |
| FLORIDA BUILDING CODE OR ANY APPLICABLE LOCAL TECHNICAL |
| AMENDMENT TO THE FLORIDA BUILDING CODE, LOCAL LICENSURE |
| REQUIREMENTS, OR OTHER LOCAL ORDINANCE PROVISIONS. |
| |
| (21) THE SALE, DELIVERY, ASSEMBLY, OR TIE-DOWN OF LAWN |
| STORAGE BUILDINGS AND STORAGE BUILDINGS NOT EXCEEDING |
| 400 SQUARE FEET AND BEARING THE INSIGNIA OF APPROVAL |
| FROM THE DEPARTMENT OF COMMUNITY AFFAIRS SHOWING |
| COMPLIANCE WITH THE FLORIDA BUILDING CODE. |
| |
| IF THE PROPOSED SHED DOES NOT FALL UNDER ONE OF THE TWO |
| EXEMPTIONS. A CONTRACTOR IS REQUIRED. |
| |
| 4. THIS PROPERTY HAS EXPIRED PERMITS. PLEASE RESOLVE. |
| |
| 5. THE PLAN PROVIDED PROPOSES TO HAVE THE SHED ADJACENT |
| TO THE EXISTING HOUSE AND STAIR. PROVIDE A DETAIL TO |
| SHOW HOW THE STAIRS WILL BE AFFECTED BY THE PROPOSED |
| SHED. SHOW OPENINGS (WINDOWS/DOORS) ON THE SIDE WHICH |
| WILL BE AGAINST THE EXIT STAIR WHICH SERVES THE 2ND |
| FLOOR UNIT, FBC 107. |
| |
| NEW COMMENT: |
| |
| A SKETCH WAS PROVIDED. SEE FBC 107, AN ARCHITECTURAL |
| QUALITY PLAN, TO SCALE, WHICH ADDRESSES ALL POTENTIAL |
| CODE RELATED ISSUES IS REQUIRED: |
| |
| 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. |
| CONSTRUCTION DOCUMENTS SHALL BE |
| DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL. |
| ELECTRONIC MEDIA DOCUMENTS SHALL BE |
| SUBMITTED WHEN APPROVED BY THE BUILDING OFFICIAL. |
| CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT |
| CLARITY TO INDICATE THE LOCATION, NATURE AND EXTENT OF |
| THE WORK PROPOSED AND SHOW IN |
| DETAIL THAT IT WILL CONFORM TO THE PROVISIONS OF THIS |
| CODE AND RELEVANT LAWS, ORDINANCES, RULES |
| AND REGULATIONS, AS DETERMINED BY THE BUILDING |
| OFFICIAL. SUCH DRAWINGS AND SPECIFICATIONS SHALL |
| CONTAIN INFORMATION, IN THE FORM OF NOTES OR OTHERWISE, |
| AS TO THE QUALITY OF MATERIALS, WHERE |
| QUALITY IS ESSENTIAL TO CONFORMITY WITH THE TECHNICAL |
| CODES. SUCH INFORMATION SHALL BE SPECIFIC, |
| AND THE TECHNICAL CODES SHALL NOT BE CITED AS A WHOLE |
| OR IN PART, NOR SHALL THE TERM "LEGAL" OR |
| ITS EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC |
| INFORMATION. ALL INFORMATION, DRAWINGS, |
| SPECIFICATIONS AND ACCOMPANYING DATA SHALL BEAR THE |
| NAME AND SIGNATURE OF THE PERSON |
| RESPONSIBLE FOR THE DESIGN. (SEE ALSO SECTION 107.3.5). |
| |
| THE PLAN PROVIDED DOES NOT MEET THIS CRITERIA. PLAN |
| SHOWS THE SHED AGAINST THE EXISTING STRUCTURE. |
| INFORMATION SUCH AS HOW THE PROPOSED SHED AFFECTS |
| EGRESS OR ANY OTHER CODE ISSUES WAS NOT PROVIDED. |
| |
| 6. THE PERMIT APPLICATION HAS WRITTEN IN THE CORNER OF |
| BOX 5 "4" SLAB BOLTED WITH BOLTED NUT." |
| |
| THIS IS NOT ADEQUATE TO SHOW WIND RESISTANCE. REFER TO |
| OTHER COMMENTS; PLANS REQUIRED. |
| |
| |