Plan Review Notes
Plan Review Notes For Permit 15030103
Permit Number 15030103
Review Stop P
Sequence Number 1
Notes
Date Text
2015-03-04 05:13:231) SHOW THE REQUIRED CLEANOUT AT THE JUNCTION OF THE
 BUILDING DRAIN AND BUILDING SEWER PER THE 2010 FL.
 BLDG. CODE, RESIDENTIAL, SEC.P3005.2.7.
 2) SHOW THE REQUIRED VENT FOR THE KITCHEN AND
 LAVATORY.WPB AMEND. TO 2010 FPC SEC. 107.2.1.
 3) SUBMIT A SLAB REPAIR DETAIL FOR THE REPLACEMENT OF
 THE CONCRETE TO INSURE THE STRUCTURAL INTEGRITY OF THE
 SLAB.2010 FBCR SEC.P2603.1.
 4) INDICATE ON THE PLAN THE LENGTH & WIDTH OF THE AREA
 OF THE CONCRETE REPAIR.WPB AMEND. TO 2010 FPC SEC.
 107.2.1.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  