Date |
Text |
2015-03-03 09:43:17 | |
| BUILDING PLAN REVIEW |
| W. P. B. PERMIT: 15030012 |
| ADD: 419 15TH ST. |
| CONT: PACE ROOFING |
| TEL: (561)642-8840 |
| E-MAIL: [email protected] |
| |
| 2010 FLORIDA BUILDING CODE W |
| * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| |
| 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| OF THE FLORIDA BUILDING CODE, BUILDING. |
| |
| 1ST REVIEW |
| DATE: |
| ACTION: DENIED |
| |
| IMPORTANT NOTICE: EFFECTIVE MARCH 30, 2015 |
| ALL PERMIT APPLICATION PLAN REVIEWS WILL BE PERFORMED |
| ELECTRONICALLY |
| UPON APPLICATION AND FEE PAYMENT DESIGN DOCUMENTS |
| SUBMISSION OPTIONS ARE AS FOLLOWS: |
| 1 UPLOAD VIA THE PROJECT DOX PORTAL WITH DIGITAL |
| SIGNATURES OF DESIGN PROFESSIONALS AS APPLICABLE; USE |
| THE REQUIRED NAMING CONVENTION FOR EACH DOCUMENT |
| 2 INCLUDE ON A CD IF DESIGN PROFESSIONAL DIGITAL |
| SIGNATURES ARE PROVIDED AS REQUIRED; USE THE REQUIRED |
| NAMING CONVENTION FOR EACH DOCUMENT |
| 3 INCLUDE ON A CD WITH ONE SET OF TRADITIONAL PAPER |
| DESIGN DOCUMENTS SIGNED AND SEALED AS REQUIRED; USE THE |
| REQUIRED NAMING CONVENTION FOR EACH DOCUMENT |
| 4 ONE SET OF TRADITIONAL PAPER DESIGN DOCUMENTS SUBJECT |
| TO ADMINISTRATIVE FEES TO DIGITIZE THE DOCUMENTS |
| ADDITIONAL INFORMATION WILL BE PROVIDED WHEN IT BECOMES |
| AVAILABLE |
| |
| 1) PLEASE NOTE THE PERMIT APPLICATION INDICATES WORK TO |
| BE COMPLETED ON A 3 STORY BUILDING. THE ENGINNERING |
| SHEET FOR THE FLAT ROOF ENHANCED FASTENING SCHEDULE FOR |
| ZONES 2 & 3 INDICATES A SINGLE STORY BUILDING OF 15 |
| FEET, WHEN LOOKING AT THE ADDRESS FOR THIS REPORT IT IS |
| FOR A DIFFERENT PROPERTY, 4805 S, DIXIE HWY. THE |
| SUBMITTED FLORIDA ROOFING REPORT FL 16730 HAS DIFFERENT |
| SUB-SYSTEMS HIGHLIGHTED AND DIFFERENT PAGES THAN THE |
| ENHANCED FASTENING ENGINEERING SHEET. 107.2.1.3 |
| ADDITIONAL INFORMATION REQUIRED, THERE IS A DISCREPANCY |
| IN PAPERWORK. |
| |
| JAMES WITMER CBO |
| SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| TEL: (561) 805-6715 |
| FAX: (561)805-6676 |
| E-MAIL: [email protected] |
| |
| |