Date |
Text |
2016-01-20 11:06:12 | RESIDENT INSPECTOR REQUIRED |
| SOILS/SITEWORK MONITORING BY A GEOTECHNICAL ENGINEER |
| REQUIRED |
| |
| W. P. B. PERMIT: 15020937 |
| ADD: 1901 S. FLAGLER DR. |
| CONT: IBIS BUILDING CORP. |
| TEL: (561)318-8408 |
| E-MAIL: [email protected] |
| |
| 2010 FLORIDA BUILDING CODE W |
| * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| 3RD REVIEW |
| DATE: JAN 20, 2016 |
| ACTION: DENIED |
| |
| 1) 3RD REQUEST. THIS PROJECT WILL REQUIRE A RESIDENT |
| INSPECTOR. |
| 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING |
| CODE, CHAPTER 1, ADMINISTRATION, 110.3.9 OTHER |
| INSPECTIONS SERVICES. THE BUILDING OFFICIAL MAY MAKE, |
| OR CAUSE TO BE MADE BY OTHERS, THE INSPECTIONS REQUIRED |
| BY SECTION 109. HE/SHE MAY ACCEPT REPORTS OF INSPECTORS |
| OF RECOGNIZED INSPECTION SERVICES, PROVIDED THAT AFTER |
| INVESTIGATION HE/SHE IS SATISFIED AS TO THEIR |
| QUALIFICATIONS AND RELIABILITY. A CERTIFICATE CALLED |
| FOR BY ANY PROVISION OF THE TECHNICAL CODES SHALL NOT |
| BE BASED ON SUCH REPORTS UNLESS THE SAME ARE IN WRITING |
| AND CERTIFIED BY A RESPONSIBLE OFFICER OF SUCH SERVICE. |
| THE BUILDING OFFICIAL MAY REQUIRE THE OWNER TO EMPLOY |
| AN INSPECTION SERVICE IN THE FOLLOWING INSTANCES: |
| |
| 1. FOR BUILDINGS OR ADDITIONS OF TYPE I OR II |
| CONSTRUCTION |
| 2. FOR ALL MAJOR STRUCTURAL ALTERATIONS |
| 3. WHERE THE CONCRETE DESIGN IS BASED ON COMPRESSIVE |
| STRENGTH (F ?C) IN EXCESS OF 3000 |
| POUNDS PER SQUARE INCH |
| 4. FOR PILE DRIVING |
| 5. FOR BUILDINGS WITH AREA GREATER THAN 20,000 SQUARE |
| FOOT |
| 6. FOR BUILDINGS MORE THAN 2 STORIES IN HEIGHT |
| 7. FOR BUILDINGS AND STRUCTURES OF UNUSUAL DESIGN OR |
| METHODS OF CONSTRUCTION |
| |
| 1A) FOR THE RESIDENT INSPECTOR PLEASE PROVIDE A RESUME' |
| OF INSPECTION EXPERIENCE ON PREVIOUS PROJECT. THE |
| RESUME' MUST BE ACCOMPANIED BY ALL CERTIFICATES AS |
| SPECIFIED HEREIN. THE BUILDING OFFICIAL OR HIS DESIGNEE |
| WILL REVIEW THE RESUME'. AFTER THE RESUME' IS REVIEWED, |
| AN INTERVIEW WILL BE SCHEDULED. UNDER NO CIRCUMSTANCES |
| WILL AN INSPECTOR BE INTERVIEWED FOR WORK WITHOUT FIRST |
| MEETING THE ABOVE CRITERIA. |
| CONTACT KEN CONRAD |
| TEL: 561-805-6666 |
| E-MAIL: [email protected] |
| |
| 1B) THE CONTRACTOR WILL PRODUCE A JOB SUMMARY OR |
| HISTORY FOR THIS TYPE OF CONSTRUCTION. THIS MAY BE |
| SUBMITTED TO KEN CONRAD BY E-MAIL. KEN CONRAD: |
| [email protected] |
| |
| 1C) NOTE FOR PAPER PLANS 3 SETS OF DOCUMENTS ARE |
| REQUIRED INCLUDING SOILS REPORTS, ENERGY CALCS AND |
| PRODUCT APPROVALS. FOR DIGITAL PLANS, AFTER PERMIT |
| ISSUANCE, THE PERMIT LIBRARIAN WILL E-MAIL YOU, THE |
| APPROVED AND BATCH STAMPED PLANS SO YOU MAY PRINT YOUR |
| PLANS, TWO SETS OF PLANS WILL NEED TO BE PRINTED IN |
| COLOR, (1) FOR THE RESIDENT INSPECTOR, THE OTHER FOR |
| THE MEP INSPECTORS. |
| |
| 2. PURSUANT TO THE RECOMMENDATION OF ARDAMAN & |
| ASSOCIATES LETTER DATED 3/31/2015, A GEOTECHNICAL |
| ENGINEER SHALL MONITOR THE SITEWORK (EXCAVATION OF |
| MUCK, COMPACTION AND FILL). IF ARDAMAN & ASSOCIATES IS |
| NOT RETAINED TO PERFORM THE MONITORING, PROVIDE |
| INFORMATION REGARDING THE COMPANY WHO WILL PROVIDE THIS |
| SERVICE. |
| |
| |
| |
| |