Plan Review Notes
Plan Review Notes For Permit 15020917
Permit Number 15020917
Review Stop B
Sequence Number 1
Notes
Date Text
2015-03-13 15:29:38****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. APPLICATION IS FOR IMPACT WINDOWS, NON IMPACT SINGLE
 HUNG WINDOW PRODUCT APPROVAL PROVIDED. THIS PRODUCT HAS
 A LIMITATION OF -45PSF, WHICH IS NOT ADEQUATE FOR
 STATED DESIGN PRESSURES.
  
 2. REVISE FLOOR PLAN TO INCLUDE ROOM DESIGNATIONS.
  
 FOR BEDROOM WINDOWS WHICH ARE LESS THAN 51" IN HEIGHT,
 NOTE EXISTING CONDITIONS (TYPE OF WINDOW) AND OPENING
 SIZE FOR BEDROOMS, FBC R310, FBC EB 604.1. THE CLEAR
 OPENING CANNOT BE REDUCED BY MORE THAN 5%.
  
 TO PROVIDE FURTHER CLARIFICATION REGARDING INFORMATION
 NEEDED FOR BEDROOM WINDOWS WHICH ARE LESS THAN 51" IN
 HEIGHT:
  
 STATE WHAT TYPE OF WINDOW IS THERE NOW IN THE BEDROOMS
 - AWNING, CASEMENT, SINGLE HUNG?
  
 STATE WHAT THE EXISTING CLEAR OPENING DIMENSIONS ARE.
 CLEAR OPENING IS THE OPENING WHICH EXISTS WHEN THE
 WINDOW IS FULLY OPEN.
  
 STATE WHAT THE PROPOSED CLEAR OPENING DIMENSIONS ARE.
 THIS CAN BE OBTAINED FROM THE MANUFACTURER.
  
  
  
  
  